Related Experiment Video
Updated: Aug 29, 2025

A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
Evaluation and optimization of a HS-SPME-assisted GC-MS/MS method for monitoring nitrosamine impurities in diverse
Shu-Han Chang1, Hui-Yu Ho1, Ching-Chia Chang1
1Food and Drug Administration, Ministry of Health and Welfare, Executive Yuan, 161-2 Kunyang St., Nangang Dist., Taipei City 11561, Taiwan.
Abstract:
The probable carcinogenic nitrosamine impurities, such as N-nitrosodiethylamine (NDEA) and N-nitrosodimethylamine (NDMA), have been detected from various pharmaceuticals in recent years. The sensitive chromatographic methods, including liquid chromatography (LC) and gas chromatography (GC), have been applied for analyzing nitrosamines in the pharmaceutical substrates, such as sartans, ranitidine and metformin. In comparison of LC, the efficacy of GC for analyzing multiple nitrosamines in diverse pharmaceuticals will be limited or attenuated owing to the chemical properties of target analytes or matrix hinderance of pharmaceutical substrates. To extend the applicability of GC analysis for multiple nitrosamines in pharmaceuticals, this study presented a gas chromatograph tandem mass (GC-MS/MS) method for monitoring 14 nitrosamines within 44 pharmaceuticals, whereas the headspace-solid phase microextraction (HS-SPME) sampling mode was introduced. Chromatographic separation was achieved on a DB-heavyWax column (30 m × 0.25 mm; i.d., 0.25 µm), whereas the HS-SPME sampling mode with a 50/30 µm DVB/CAR/PDMS extracting fiber was applied for comparison of the direct injection mode. Meanwhile, the HS-SPME conditions were optimized to evaluate the effects of the parameters on analyzing total nitrosamines in pharmaceuticals by GC-MS/MS. The optimal conditions of HS-SPME were as follows: extracting solution of 90% NaCl, HS incubation time 1 min, SPME adsorbing at 80 ℃ for 30 min, and desorbing at 250 ℃ for 5 min. The limit of quantification (LOQ) for 14 nitrosamines in pharmaceutical matrices under the optimal conditions was 0.05 μg/g for the optimal HS-SPME, whereas the value was 0.05-0.25 μg/g for direct injection.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
04:19Author Spotlight: An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023