Related Experiment Video
Updated: Aug 29, 2025

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Comparison of biomechanical analysis of four different tibial tunnel fixations in a bovine model
Firat Erpala1, Tahir Ozturk2, Mehmet Burtac Eren2
1Department of Orthopaedics and Traumatology, Cesme Alpercizgenakat State Hospital Izmir, Çeşme/İzmir, Turkey.
Background:
To determine the ideal fixation technique for an ACL reconstruction with a hamstring graft, multiple studies have been undertaken to define the initial biomechanical properties of tibial fixation.
Purpose:
The aim of this study was to compare the biomechanical properties of tibial fixation methods by creating single or hybrid systems.
Methods:
Bovine tibias and forefoot digital extensor tendons were prepared with four different tibial anterior cruciate ligament fixation methods and compared biomechanically. Fixation materials included polyethylene Ultrabraid high-strength sutures, Biosure interference screws (Smith and Nephew, Memphis, TN, USA), staples (Smith and Nephew, Richards Regular Fixation Staples without Spikes, Memphis, TN, USA), and knotless suture anchors (Multifix-S PEEK) (Smith and Nephew, Memphis, TN, USA). Four groups (n = 5 specimens) were established - group I: single fixation with interference screws; group II: single fixation with knotless anchors; group III: hybrid fixation with interference screws and staples; group IV: hybrid fixation with interference screws and knotless anchors. Each specimen underwent evaluations for cyclic displacement, cyclic stiffness, initial loading strength, ultimate failure load, pull-out displacement, and pull-out stiffness.
Results:
All specimens completed cyclic loading and load-to-failure. The cyclic displacement in group II, which had a single fixation, indicated significantly greater elongation compared with the other groups (P = 0.002). The hybrid systems were more rigid than the single systems in terms of cyclic stiffness, and no statistically significant difference was observed between the hybrid systems (P = 0.461). Group IV was significantly superior in terms of the ultimate failure load (P = 0.004). No statistically significant differences were noted between the groups for pull-out displacement or pull-out stiffness.
Conclusion:
Single fixation with bioscrews as an in-tunnel tibia fixation method was as successful as hybrid systems. Multifix-S PEEK knotless suture anchors, which can be combined with bioscrews, can be a superior fixation alternative due to its flexibility and ultimate failure load values.