Influence of atmospheric pressure changes on dentin bond strength of conventional, bulk-fill and single-shade resin
Secil Ozkan Ata1,2, Canan Akay1,3,4, Emre Mumcu1,3,5
1Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey.
Introduction:
The purpose of this study was to investigate the dentin bond strength of composite resins in response to environmental pressure changes.
Methods:
Ninety extracted human molar teeth were used. A mould (3 mm x 4 mm) was adapted on dentin, resin composites (conventional [n = 30] and single-shade composites [Ohmnicroma] [n = 30]) were filled in two increments of 2 mm. The bulk-fill composites (n = 30) were filled with one 4 mm increment. The specimens were stored for 30 days in artificial saliva. The specimens were exposed to hyperbaric pressure (283.6 kPa; 2.8 atmospheres absolute [atm abs]) or hypobaric pressure (34.4 kPa; 0.34 atm abs) once daily for 30 days and the control group was stored at atmospheric pressure for 30 days. The bond strength was tested with a universal testing machine and the failures were examined with a stereomicroscope and scanning electron microscope. Statistical analyses were performed using analysis of variance with post hoc tests, and the Weibull analysis.
Results:
Regardless of environmental pressure changes, the bulk-fill composites showed the highest bond strength. There was no significant difference in bond strength between the hypobaric and atmospheric pressure (control) groups after 30 days in all resins. The hyperbaric group showed lower bond strength for bulk-fill composites than the control group.
Conclusions:
Dentists experienced in diving and aviation medicine should definitely take part in the initial and periodic medical examinations of divers and aircrew to give appropriate treatment. Bulk-fill composite resins can be preferred in divers and aircrew due to high bond strength values.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Bonding and Strength of Aggregate
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...
Relation Between Tensile Strength and Compressive Strength of Concrete