Related Experiment Video
Updated: Aug 28, 2025

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Effects of Retroperitoneal or Transperitoneal Pneumoperitoneum on Inferior Vena Cava Hemodynamics and Cardiopulmonary
Cheng Peng1,2, Hao Shen3, Senming Cao2
1Medical School of Chinese PLA, Beijing, China.
Abstract:
To evaluate the effects of CO2 pneumoperitoneum on venous hemodynamics and cardiopulmonary function during transperitoneal or retroperitoneal laparoscopic surgery. A single-institution prospective study. Forty-three patients with renal-cell carcinoma undergoing retroperitoneal (22) or transperitoneal (21) laparoscopic partial nephrectomy were enrolled. Hemodynamic functions were monitored by minimally invasive FloTrac/Vigileo system. Transesophageal echocardiography was used to measure the diameter and blood flow of the inferior vena cava (IVC). Measured parameters were recorded at baseline, 10, 30, 60 minutes following insufflation to 14 mm Hg and 10 minutes following desufflation. For hemodynamic changes in the transperitoneal laparoscopic surgery (TPL) and retroperitoneal laparoscopic surgery (RPL), transperitoneal CO2 insufflation resulted in a rapid parallel increase in central intravenous pressure (CVP), peak airway pressure (AWP), and IVC blood flow velocity after the first 30 minutes of pneumoperitoneum (p < 0.05). In contrast, CVP, AWP, and IVC blood flow velocity increased progressively in RPL. The variation of those parameters was significantly lower than that of TRL (p < 0.001; p = 0.002; p = 0.004). The mean maximum CVP in the two groups was 20 and 16 mm Hg, respectively. The IVC diameter at the cavoatrial junction was significantly reduced in TPL after 10 minutes of insufflation, but it remained unchanged in RPL throughout the surgery. For cardiopulmonary function changes, heart output decreased after a short period of pneumoperitoneum, but no statistical differences were observed between the two groups. The increments of partial pressure of arterial carbon dioxide and end-tidal carbon dioxide tension were significantly higher in RPL than TPL (p < 0.001; p < 0.001). Compared with retroperitoneal pneumoperitoneum, transperitoneal pneumoperitoneum has significant effects on IVC hemodynamics. Elevated intra-abdominal pressure (IAP) causes higher AWP and venous return resistance, which lead to the significant increase of CVP during transperitoneal approach. Adjusting the balance between IAP and CVP might be an effective way to control intravenous bleeding. Registration number: ChiCTR2000038291.
More Related Videos
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Veins of the Abdomen and Pelvis
The inferior vena cava is fed by numerous smaller veins. The lumbar veins, for instance, drain the posterior abdominal wall, emptying both directly into the inferior vena cava and into the...
Pulmonary Embolism I: Introduction
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Pneumothorax-II
Clinical Manifestations:
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.