Respiratory motion correction in F-18-FDG PET/CT impacts lymph node assessment in lung cancer patients
Benjamin Noto1,2, Wolfgang Roll3, Laura Zinken3
1Department of Nuclear Medicine, University Hospital Münster, Münster, Germany. Benjamin.Noto@ukmuenster.de.
Backgrounds:
Elastic motion correction in PET has been shown to increase image quality and quantitative measurements of PET datasets affected by respiratory motion. However, little is known on the impact of respiratory motion correction on clinical image evaluation in oncologic PET. This study evaluated the impact of motion correction on expert readers' lymph node assessment of lung cancer patients.
Methods:
Forty-three patients undergoing F-18-FDG PET/CT for the staging of suspected lung cancer were included. Three different PET reconstructions were investigated: non-motion-corrected ("static"), belt gating-based motion-corrected ("BG-MC") and data-driven gating-based motion-corrected ("DDG-MC"). Assessment was conducted independently by two nuclear medicine specialists blinded to the reconstruction method on a six-point scale [Formula: see text] ranging from "certainly negative" (1) to "certainly positive" (6). Differences in [Formula: see text] between reconstruction methods, accounting for variation caused by readers, were assessed by nonparametric regression analysis of longitudinal data. From [Formula: see text], a dichotomous score for N1, N2, and N3 ("negative," "positive") and a subjective certainty score were derived. SUV and metabolic tumor volumes (MTV) were compared between reconstruction methods.
Results:
BG-MC resulted in higher scores for N1 compared to static (p = 0.001), whereas DDG-MC resulted in higher scores for N2 compared to static (p = 0.016). Motion correction resulted in the migration of N1 from tumor free to metastatic on the dichotomized score, consensually for both readers, in 3/43 cases and in 2 cases for N2. SUV was significantly higher for motion-corrected PET, while MTV was significantly lower (all p < 0.003). No significant differences in the certainty scores were noted.
Conclusions:
PET motion correction resulted in significantly higher lymph node assessment scores of expert readers. Significant effects on quantitative PET parameters were seen; however, subjective reader certainty was not improved.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...