Risks of decoupling from China on low-carbon technologies
Michael R Davidson1,2, Valerie J Karplus3, Joanna I Lewis4
1School of Global Policy and Strategy, University of California, San Diego, La Jolla, CA, USA.
Abstract:
For most technologies, the cure is likely worse than the disease.
More Related Videos
Related Concept Videos
Fast Decoupled and DC Powerflow
272
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
272
Global Regulatory Systems
66
Global regulatory systems in bacteria enable rapid and coordinated responses to environmental changes by integrating sensory inputs with gene expression, ensuring efficient adaptation to fluctuating conditions. Key global regulatory mechanisms include regulons, two-component systems, sigma factors, and secondary messengers.Regulons and Global RegulatorsA regulon is a collection of genes and operons controlled by a common global regulator. These regulators enable bacteria to prioritize resource...
66
¹³C NMR: ¹H–¹³C Decoupling
1.2K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.2K
Energy Losses in Transformers
944
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
944
Conservation of AC Power
382
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
382
Nuclear Power
8.1K
Controlled nuclear fission reactions are used to generate electricity. Any nuclear reactor that produces power via the fission of uranium or plutonium by bombardment with neutrons has six components: nuclear fuel consisting of fissionable material, a nuclear moderator, a neutron source, control rods, reactor coolant, and a shield and containment system.
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
8.1K


