Related Experiment Video
Updated: Aug 28, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Ease and comfort of pre-oxygenation with high-flow nasal oxygen cannulae vs. facemask: a randomised controlled trial
A F Merry1,2, H van Waart1, S J Allen2
1Department of Anaesthesiology, Faculty of Medical and Health Science, University of Auckland, New Zealand.
Abstract:
The Difficult Airway Society recommends that all patients should be pre-oxygenated before the induction of general anaesthesia, but this may not always be easy or comfortable and anaesthesia may often be induced without full pre-oxygenation. We tested the hypothesis that high-flow nasal oxygen cannulae would be easier and more comfortable than facemasks for pre-oxygenation. We randomly allocated 199 patients undergoing elective surgery aged ≥ 10 years to pre-oxygenation using either high-flow nasal oxygen or facemask. Ease and comfort were assessed by anaesthetists and patients on 10-cm visual analogue scale and six-point smiley face scale, respectively. Secondary endpoints included end-tidal oxygen fraction after securing a definitive airway and time to secure an airway. A mean difference (95%CI) between groups in ratings of -0.76 (-1.25 to -0.27) cm for ease of use (p = 0.003) and -0.45 (-0.75 to -0.13) points for comfort (p = 0.006), both favoured high-flow nasal oxygen. A mean difference (95%CI) between groups in end-tidal oxygen fraction of 3.89% (2.41-5.37%) after securing a definitive airway also favoured high-flow nasal oxygen (p < 0.001). There was no significant difference between groups in the number of patients with hypoxaemia (Sp O2 < 90%) or severe hypoxaemia (Sp O2 < 85%) lasting ≥ 1 min or ≥ 2 min; in the proportion of patients with an end-tidal oxygen fraction < 87% in the first 5 min after tracheal intubation (52.2% vs. 58.9% in facemask and high-flow nasal oxygen groups, respectively; p = 0.31); or in time taken to secure an airway (11.6 vs. 12.2 min in facemask and high-flow nasal oxygen groups, respectively; p = 0.65). In conclusion, we found pre-oxygenation with high-flow nasal oxygen to be easier for anaesthetists and more comfortable for patients than pre-oxygenation with a facemask, with no clinically relevant differences in end-tidal oxygen fraction after securing a definitive airway or time to secure an airway. The differences in ease and comfort were modest.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Cardiopulmonary Resuscitation II: ACLS Airway Management