Related Experiment Video
Updated: Aug 28, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Comparative Evaluation of Microleakage of Various Restorative Materials in Pulpotomized Primary Molars - In Vitro
Jeswin M Thomas1, Sham S Bhat2, A Esai Amutha Prabha3
1Reader, Department of Pedodontics, Pushpagiri college of Dental Sciences, Thiruvalla, Kerala, India.
Background And Objectives:
Conventionally, stainless steel crown (SSC) is the preferred material for the restoration of pulpotomized primary molars. However, in situations where stainless steel cannot be used necessity for other restorative material arises.
Aim:
The aim of this study is to assess the microleakage of several coronal seal materials in pulpotomized primary molars- in vitro.
Methodology:
Seventy-five primary molars were prepared with proximo-occlusal cavities. Restoration was done with Zinc oxide eugenol cement, SSC, composite resin, resin-modified glass-ionomer cement (GIC), and amalgam. Microleakage was assessed using dye penetration technique with stereomicroscope and scanning electron microscope.
Statistical Analysis And Results:
The Kruskal-Wallis and Mann-Whitney tests were used to statistically analyze the results.
Conclusion:
With regard to this present study composite resin and resin-modified GIC offers a good alternative for SSC.