A Comparison of Xenograft Graft Material and Synthetic Bioactive Glass Allograft in Immediate Dental Implant Patients
Manish Goutam1, Namish Batra2, K Jyothirmayee3
1Department of Prosthodontics, Dental Institute, Rajendra Institute of Medical Sciences, Ranchi, Jharkand, India.
Objectives:
The objective of the study is to compare xenograft graft material and synthetic bioactive glass allograft in immediate dental implant patients.
Materials And Methods:
Forty patients were grouped as Group A patients (xenograft graft material, BioOss) and Group B (synthetic allograft material, Perio Glas) and immediate implant placement was done. Plaque index, gingival index, probing depth, and bone resorption were compared at different intervals.
Results:
A nonsignificant difference was observed in all parameters at different interval of time (P > 0.05) recorded at mesial, distal, buccal, and lingual side.
Conclusion:
Xenograft (Bio Oss) and synthetic allograft (PerioGlas) found to be effective graft materials treatment choice.