In situ formic acid dehydrogenation observation using a UV-vis-diffuse-reflectance spectroscopy system
Risheng Li1,2, Tetsuya Kodaira2, Hajime Kawanami1,2
1Graduate School of Pure and Applied Science, University of Tsukuba, Tsukuba, 305-8577, Japan.
Summary
Researchers developed a new spectroscopy system for real-time monitoring of catalytic formic acid dehydrogenation. This method provides reliable data without mechanical errors, enabling continuous observation of gas concentration.
Area of Science:
- Catalysis and Chemical Engineering
- Spectroscopy and Analytical Chemistry
Background:
- Catalytic formic acid dehydrogenation is a key reaction for hydrogen production.
- Accurate monitoring of reaction intermediates and products is crucial for understanding and optimizing catalytic processes.
- Existing methods for monitoring gas concentration can suffer from mechanical errors and limitations.
Purpose of the Study:
- To develop and validate a novel in situ/operando UV-vis-diffuse-reflectance spectroscopy system.
- To enable continuous and reliable monitoring of gas concentration during catalytic formic acid dehydrogenation.
- To overcome limitations of traditional gas measurement techniques.
Main Methods:
- A newly developed in situ/operando UV-vis-diffuse-reflectance spectroscopy system was employed.
- High-speed stirring was used to control gas concentration in the center of a round cell.
- The system was applied to monitor catalytic formic acid dehydrogenation.
Main Results:
- The developed spectroscopy system demonstrated a high signal-to-noise (S/N) ratio.
- Reliable spectral data were obtained without mechanical errors associated with gas meters.
- Continuous monitoring of gas concentration during the catalytic reaction was successfully achieved.
Conclusions:
- The novel UV-vis-diffuse-reflectance spectroscopy system offers a robust and accurate method for in situ/operando reaction monitoring.
- This technique facilitates continuous observation of catalytic formic acid dehydrogenation, aiding process optimization.
- The system provides a valuable alternative to conventional gas monitoring methods in catalytic studies.
More Related Videos
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
4.5K
In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
4.5K
UV–Vis Spectrometers
1.5K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.5K
Spectroscopy of Carboxylic Acid Derivatives
2.5K
Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and...
2.5K
UV–Vis Spectroscopy: Woodward–Fieser Rules
25.2K
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given...
25.2K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
2.9K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for...
2.9K
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
6.0K
Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the...
6.0K