Comparing laryngeal view in neutral and sniff position during video laryngoscopy-guided intubation
Uranus Khordad1, Mohamad Reza Rafiei2, Mehrshad Namazi3
1Surgical and Trauma Research Center, AJA University of Medical Science, Tehran. Oranouskhordad@yahoo.com.
Abstract:
Appropriate positioning of the head is a crucial step for a successful intubation. Laryngoscopy is a commonly used method to facilitate the intubation process. This study evaluated the quality of intubation and its difficulty in sniff and neutral position. This was a clinical randomized trial, conducted in 2021 in Aja university of medical sciences. 40 patients, meeting the inclusion criteria were randomly assigned to sniff and neutral group and were intubated with standard procedure. The required time, number of attempts, laryngeal view, cord status, and the need for maneuver were evaluated between the two positions. Overall, 60 patients were intubated in sniff and 60 in neutral position. 51 of them were male and 69 were female. The mean intubation time was (17/15 ± 8/00) and (16/65 ± 8/66) seconds in neutral and sniff position, respectively (p-value = 0.181). There was no statistically significant difference in the required time. Additionally, 45 patients were intubated in first attempt and 15 were intubated after the second attempt in each group. There was no difference in any difficulty-related parameter of the two groups. No significant difference between the required time, attempt, or any other parameter was detected between the sniff and neutral groups. Evidence suggests that there is no superiority regarding these two positions and the decision should be made by the physician on a case-by-case basis.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...