Related Experiment Video

Updated: Aug 28, 2025

Simple Continuous Glucose Monitoring in Freely Moving Mice
03:25

Simple Continuous Glucose Monitoring in Freely Moving Mice

Published on: February 24, 2023

5.8K

Minimally Invasive Implant Type Electromagnetic Biosensor for Continuous Glucose Monitoring System: In Vivo

Jagannath Malik, Seongmun Kim, Jong Mo Seo

    IEEE Transactions on Bio-Medical Engineering
    |September 16, 2022
    PubMed
    Summary

    A new durable, implantable electromagnetic sensor offers long-term continuous glucose monitoring (CGM) for diabetes management. This highly sensitive sensor accurately tracks blood glucose levels, improving upon current short-term continuous glucose monitoring systems.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Timing of Antidiabetic Medication Initiation and Risk of Cardiovascular Events and Mortality.

    JAMA network open·2026
    Same author

    Semaglutide and Risk of Adult-Onset Seizure: A Target Trial Emulation.

    Neurology·2026
    Same author

    Infective Endocarditis in a Previously Healthy Adolescent Caused by <i>Streptococcus sanguinis</i>: Diagnostic Challenges and Clinical Implications.

    Infection & chemotherapy·2026
    Same author

    Multimode OAM antenna with reduced beam divergence for 6G networks.

    Scientific reports·2026
    Same author

    A case of early-onset ovarian cancer following bariatric surgery: Highlighting the need for caution in genetically predisposed obese patients.

    Turkish journal of surgery·2026
    Same author

    Efficacy and safety of combining empagliflozin in people with type 2 diabetes mellitus uncontrolled with metformin and sitagliptin: A randomised, double-blind, multicentre, therapeutic confirmatory phase 3 clinical trial.

    Diabetes, obesity & metabolism·2025

    Area of Science:

    • Biomedical Engineering
    • Sensor Technology
    • Diabetes Technology

    Background:

    • Continuous glucose monitoring systems (CGMS) are increasingly preferred over self-blood glucose monitoring (SBGM).
    • Current commercial CGMS have limited lifespans, lasting only weeks to months.
    • There is a need for durable, long-term glucose monitoring solutions.

    Purpose of the Study:

    • To present a durable, highly sensitive, and minimally invasive implantable electromagnetic sensor for continuous glucose monitoring (CGM).
    • To develop a sensor capable of tracking minute changes in blood glucose levels (BGL).
    • To assess the sensor's suitability for long-term CGM applications.

    Main Methods:

    • Utilizing strong oscillating near-field to detect changes in interstitial fluid (ISF) and blood dielectric permittivity correlated with BGL.

    More Related Videos

    Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
    08:19

    Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing

    Published on: June 1, 2012

    14.5K
    An Implantable System For Chronic In Vivo Electromyography
    09:52

    An Implantable System For Chronic In Vivo Electromyography

    Published on: April 21, 2020

    10.8K

    Related Experiment Videos

    Last Updated: Aug 28, 2025

    Simple Continuous Glucose Monitoring in Freely Moving Mice
    03:25

    Simple Continuous Glucose Monitoring in Freely Moving Mice

    Published on: February 24, 2023

    5.8K
    Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
    08:19

    Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing

    Published on: June 1, 2012

    14.5K
    An Implantable System For Chronic In Vivo Electromyography
    09:52

    An Implantable System For Chronic In Vivo Electromyography

    Published on: April 21, 2020

    10.8K
  • Employing biocompatible packaging material (polyolefin) to minimize foreign body reactions and enhance sensor stability.
  • Evaluating sensor performance in vivo on rodent models using intravenous glucose and insulin tolerance tests.
  • Main Results:

    • The proposed sensor demonstrated real-time tracking of blood glucose level (BGL) changes, correlating highly (R² > 0.9) with a commercial blood glucose meter.
    • Biocompatible polyolefin packaging was used, and its thickness effect on sensor sensitivity was examined in vivo.
    • The sensor successfully tracked minute changes in BGL during in vivo experiments.

    Conclusions:

    • The developed electromagnetic sensor is suitable for long-term continuous glucose monitoring applications with high accuracy.
    • The study provides a novel approach for developing long-term CGM systems using implantable electromagnetic sensors.
    • In vivo evaluations confirmed the sensor's excellent ability to track blood glucose level fluctuations.