Computational fluid dynamics-based optimal installation strategy of air purification system to minimize NOX exposure
Yup Yoo1, Jaeseop Kim2, Seongbin Ga3
1Green Materials and Processes R&D Group, Korea Institute of Industrial Technology, 55 Jonga-ro, Ulsan 44413, Republic of Korea; Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Republic of Korea.
Abstract:
At public bus stops, NOX pollutants discharged by regularly stopping buses quickly accumulate, exposing waiting passengers to high levels of air pollutants, which creates a threat to public health. The environmental protection agency (EPA) presents air quality standards for NOX, a significant pollutant that causes lung diseases such as asthma when exposed to the human body. To handle this problem, air purification systems are installed inside bus stops in many public places. However, it is challenging to maintain a low concentration of NOX inside public bus stops due to the persistent inflow of bus exhaust gas. Therefore, it is crucial to design an optimal location for an air purification system to meet air environment standards for respiratory areas. This study proposed a computational fluid dynamics (CFD)-based optimal installation strategy for an air purification system to minimize NOX exposure inside a public bus stop. The CFD model was developed to numerically analyze NO2 exposure with the actual design value for a public bus stop in Ulsan, South Korea. The local NO2 concentration was evaluated in the human breathing zone. The case study was performed according to the locations of the inlet and outlet of the air purification system. A transient CFD simulation was performed to analyze the effect of the air purification system on pollutants generated from the stationary bus by time flow in various cases. NO2 concentration and exposure reduction effectiveness (ERE) were analyzed and compared for each case in the breathing zone. In the optimal case, the ERE of NO2 was confirmed to be 35.9 %, and the NO2 concentration according to the air quality standards of EPA could be maintained at 0.1 ppm or less. The theoretical framework proposed in this study can be generalized to design air purification systems for general external facilities.
More Related Videos
08:59Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
Published on: May 22, 2020
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023