Related Experiment Video
Updated: Aug 28, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Real-time continuous glucose monitoring improves glycemic control and reduces hypoglycemia: Real-world data
Ravi Kant1, Mc Anto Antony1, David Geurkink2
1Division of Endocrinology, Diabetes and Nutrition, Medical University of South Carolina, AnMed Campus, Anderson, SC 29621, United States.
Aim:
To study the effect of real time continuous glucose monitor (RT-CGM) use on glycemic parameters in patients with diabetes mellitus (DM) in real world practice.
Methods:
We retrospectively studied 91 adult subjects with DM who had been using Dexcom™ RT-CGM. Two consecutive hemoglobin A1c (HbA1c), both prior to and after at least 3 months of RT-CGM initiation, were collected. A total of 31 subjects completed a 5-14 day user blinded CGM using a Freestyle Libre™ prior to RT-CGM initiation. The first two week period following at least 3 months use of RT-CGM was analyzed for CGM metrics.
Results:
A total of 51.6 % of subjects had T1DM, 34.1 % used continuous subcutaneous insulin infusion (CSII), and 62.6 % had DM for > 10 years. Both HbA1c obtained following RT-CGM initiation decreased significantly compared to baseline (8.11 + 1.47% vs 7.69 + 1.25 %; P = 0.002 & 8.16 + 1.51 % vs 7.62 + 1.06 %; P = 0.001). Subjects with baseline HbA1c > 7.0 % showed even more robust reduction in both HbA1c after RT-CGM initiation (8.74 + 1.24 % vs 7.99 + 1.22 %; P = 0.000 & 8.74 + 1.32 % vs 7.85 + 1.07 %; P = 0.001). On comparison of CGM metrics, there was a significant reduction in time spent in hypoglycemia (sugars < 70 mg/dl) including severe hypoglycemia (sugars < 54 mg/dl) after initiation of the RT-CGM (9.16 + 8.68 % vs 1.29 + 2.21 %; P = <0.001 & 4.58 + 5.43 % vs 0.28 + 0.58 %; P = <0.001). CoV of glucose was also decreased significantly (39.61 + 9.36 % vs 31.06 + 6.74 %; P = <0.001) with RT- CGM use.
Conclusion:
RT-CGM use for at least 3 months in patients with DM results in meaningful HbA1c reductions with stable glycemic control without increasing the risk of hypoglycemia.
Related Concept Videos
Hypoglycemia and Glucagon
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Oral Hypoglycemic Agents: Glinides