Cardiac output monitoring with pulmonary versus trans-cardiopulmonary thermodilution in left ventricular assist
Begoña Quintana-Villamandos1,2, Mónica Barranco1, Ignacio Fernández1
1Department of Anesthesiology and Intensive Care, Gregorio Marañón Hospital, Madrid, Spain.
Abstract:
Cardiac output (CO) measurement is mandatory in patients with left ventricular assist devices (LVADs). Thermodilution with pulmonary artery catheter (PAC) remains the clinical gold standard to measure CO in these patients, however it is associated with several complications. Therefore, the agreement between PAC and new, minimally invasive monitoring methods in LVAD needs to be further investigated. The aim of this study was to assess the accuracy and reliability of transpulmonary thermodilution with a PiCCO2 monitor compared with pulmonary artery thermodilution with PAC in a LVAD. Continuous-flow LVADs were implanted in six mini-pigs to assist the left ventricle. We studied two methods of measuring CO-intermittent transpulmonary thermodilution (COTPTD) by PiCCO2 and intermittent pulmonary artery thermodilution by CAP, standard technique (COPTD)-obtained in four consecutive moments of the study: before starting the LVAD (basal moment), and with the LVAD started in normovolemia, hypervolemia (fluid overloading) and hypovolemia (shock hemorrhage). A total of 72 paired measurements were analysed. At the basal moment, COTPTD and COPTD were closely correlated (r 2 = 0.89), with a mean bias of -0.085 ± 0.245 L/min and percentage error of 16%. After 15 min of partial support LVAD, COTPTD and COPTD were closely correlated (r 2 = 0.79), with a mean bias of -0.040 ± 0.417 L/min and percentage error of 26%. After inducing hypervolemia, COTPTD and COPTD were closely correlated (r 2 = 0.78), with a mean bias of -0.093 ± 0.339 L/min and percentage error of 13%. After inducing hypovolemia, COTPTD and COPTD were closely correlated (r 2 = 0.76), with a mean bias of -0.045 ± 0.281 L/min and percentage error of 28%. This study demonstrates a good agreement between transpulmonary thermodilution by PiCCO monitor and pulmonary thermodilution by PAC in the intermittent measurement of CO in a porcine model with a continuous-flow LVAD.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiomyopathy II: Dilated Cardiomyopathy