Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective
1Department of Paediatrics, Malankara Orthodox Syrian Church (MOSC) Medical College Hospital, Kolenchery, Kochi, Kerala, India.
Aim:
To assess the usefulness and efficacy of pulse oximetry (disappearance/reappearance of plethsmographic waves) as a method of non-invasive blood pressure monitoring in neonates.
Objective:
To investigate the reliability of the plethysmographic wave form of the pulse oximeter to measure the systolic blood pressure.
Study Setting:
A prospective observational study was done to assess usefulness and efficacy of pulse oximetry (disappearance/reappearance of plethysmographic waves) as a method of non-invasive blood pressure monitoring in neonates.
Material And Methods:
The study was conducted among 500 neonates to investigate the reliability of the plethysmographic waveform of the pulse oximeter to measure the systolic blood pressure as it is a easy way to perform and non invasive.
Statistical Analysis Used:
The results will compare and analyse statistically by Pearson correlation co-efficient. Regression modeling will carried out to explain the relationship of non-invasive blood pressure with mean DP and RP and attempted to predict the non-invasive blood pressure from mean DP/mean RP.
Results:
The study results revealed that NIBP systolic and diastolic both correlated with DP and RP of pulse oximetry plethysmograph.
Conclusion:
Study concluded that pulse oximetry is a reliable tool in measuring blood pressure in neonates (appearance and disappearance of plethysmogram).
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.