Related Experiment Video
Updated: Aug 28, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Intracardiac electrogram characteristics of intramural outflow tract ventricular arrhythmias
Kivanc Yalin1, Tolga Aksu2, Baris Ikitimur1
1Department of Cardiology, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Background:
Annotation of earliest depolarization which depends on maximum dV/dt of unipolar-electrograms and unipolar QS morphology identify site of origin for ventricular premature contractions (VPC). However, identification of unipolar QS morphology has limitations due to low spatial resolution. This study aims to compare electrogram characteristics at successful ablation site in patients with outflow tract (OT) VPC.
Methods:
Local activation time (LAT), duration, and voltage data of each bipolar- and unipolar-electrogram at the successful ablation sites from the right ventricle OT (RVOT) and the left ventricle OT (LVOT) cases were analyzed.
Results:
Forty-four of 60 (73%) of patients were ablated from RVOT and in 16/60 (27%) required ablation from both sides. All patients had acute VPC suppression. Bipolar-electrogram-QRS onset was earlier (36.4 ± 14.5 ms vs 26.3 ± 7.4 ms, p = 0.01), duration of bipolar-electrogram was shorter (56.9 ± 18.9 ms vs 78.9 ± 21.8 ms, p = 0.002), and bi-voltage amplitude was higher (3.2 ± 2.3 mV vs 1.4 ± 1.1 mV, p = 0.07) for patients with RVOT-only ablation. Mean bipolar-unipolar-electrogram difference was 4.4 ± 4.5 ms in the RVOT group vs 12.8 ± 4.9 ms in RVOT + LVOT group (p < 0.001). Unipolar QS morphology was recorded in 3.0 ± 3.9 vs 3.6 ± 1.8 cm2 in RVOT and RVOT + LVOT group, respectively (p = 0.41). Unipolar-electrogram revealed W pattern in 3/44 of RVOT vs 5/16 of RVOT + LVOT group, respectively (p = 0.01). In 18/60 (30%) of patients, unipolar QS was not identified at successful ablation site.
Conclusion:
QS in unipolar-electrogram was not a perfect predictor for successful ablation sites. Analysis of bipolar voltage amplitude and duration with bipolar-unipolar-electrogram time difference may identify presence of a deeper source.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:19Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Mechanism of Cardiac Arrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...