The broad impact of functional lumen imaging probe panometry in addition to high-resolution manometry in an esophageal clinical practice
Related Experiment Video
Updated: Aug 28, 2025

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
Ashton Ellison1, Anh D Nguyen1, Jesse Zhang1
1Center for Esophageal Diseases, Baylor University Medical Center, part of Baylor Scott & White, Dallas, TX, USA.
Abstract:
High-resolution manometry (HRM) with the Chicago Classification (CC) is the standard paradigm to define esophageal motility disorders. Functional lumen imaging probe (FLIP) panometry utilizes impedance planimetry to characterize esophageal compliance and secondary peristalsis. The aim of this study was to explore the clinical impact of FLIP panometry in addition to HRM. A retrospective chart review was performed on FLIP panometry cases utilizing the 322N catheter. Cases with prior foregut surgeries or botulinum injection within 6 months of FLIP panometry were excluded. EGJ-diameter and distensibility index (DI) and secondary contraction patterns at increasing balloon volumes were recorded. An EGJ-DI of ≥2.8 mm2/mm Hg at 60 mL was considered as a normal EGJ distensibility. CC diagnosis, Eckhardt score, Brief Esophageal Dysphagia Questionnaire, and clinical outcomes were obtained for each FLIP case. A total of 186 cases were included. Absent contractility and achalasia types 1 and 2 showed predominantly absent secondary contraction patterns, while type 3 had a variety of secondary contractile patterns on FLIP panometry. Among 77 cases with EGJ outflow obstruction (EGJOO), 60% had a low EGJ-DI. Among those with no motility disorder or ineffective esophageal motility on HRM, 27% had a low DI and 47% had sustained contractions on FLIP, raising concern for an esophageal dysmotility process along the achalasia and/or spastic spectrum. FLIP panometry often confirmed findings on HRM in achalasia and absent contractility. FLIP panometry is useful in characterizing EGJOO cases. Spastic features on FLIP panometry may raise concern for a motility disorder on the spastic spectrum not captured by HRM. Further studies are needed on FLIP panometry to determine how to proceed with discrepancy with HRM and explore diagnoses beyond the CC.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...

