Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Frequency-Division-Multiplexed Multicomponent Gas Sensing with Photothermal Spectroscopy and a Single NIR/MIR
Feifan Chen1,2, Shoulin Jiang2, Hoi Lut Ho1
1Department of Electrical Engineering and Photonics Research Institute, The Hong Kong Polytechnic University, Hung Hom, Kowloon 999077, Hong Kong, China.
Abstract:
We report a multicomponent gas sensor based on hollow-core fiber (HCF) photothermal spectroscopy with frequency-division multiplexing (FDM). A single antiresonant HCF (AR-HCF) is used as the gas cell, which supports broadband transmission from near-infrared (NIR) to mid-infrared (MIR), covering the absorption lines of water vapor (H2O) at 1.39 μm, carbon dioxide (CO2) at 2.00 μm, and carbon monoxide (CO) at 4.60 μm. The NIR and MIR pump lasers at the above wavelengths are coupled into the AR-HCF from the opposite ends and modulated at 7.5, 8.0, and 8.5 kHz, respectively, to produce photothermal phase modulations at different frequencies. A common probe Fabry-Perot interferometer at 1.55 μm is adopted to detect the phase modulations, which are demodulated simultaneously using three lock-in amplifiers at the respective second harmonic frequencies. With a 13-cm-long AR-HCF, simultaneous detections of H2O, CO2, and CO are demonstrated with the limits of detection (LODs) of 2.7 ppm, 25 ppb, and 9 ppb for 1 s lock-in time constant, respectively. The LODs go down to 222, 1.5, and 0.6 ppb, respectively, for 1000 s averaging time. The photothermal signals of CO and CO2, which are humidity-level dependent, are well calibrated by use of the measured H2O signal. The multicomponent gas sensor is compact in configuration and shows good stability with signal fluctuation less than 1.7% over 2 h.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
IR Spectrometers
Flame Photometry: Overview
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...