Related Experiment Video
Updated: Aug 28, 2025

06:16
Author Spotlight: Advancing Thrombolytic Testing by Integrating Flow Dynamics in In Vitro Models
Published on: April 19, 2024
1.1K
Comparison of Two Different Rota-Flush Solutions in Patients Undergoing Rotational Atherectomy: A Randomized,
Zhiqing Guo1,2, Hao Hu1,2, Jinsheng Hua1,2
1Department of Cardiology, The Affiliated Anhui Provincial Hospital of Anhui Medical University, Hefei, No. 17 Lu jiang Road, Hefei, 230001, Anhui, China.
Cardiology and Therapy
|September 21, 2022
Summary
Heparin rota-flush solution did not increase slow flow/no-reflow during rotational atherectomy (RA). However, it led to more coronary spasm, suggesting traditional solutions are preferable for RA procedures.
Area of Science:
- Cardiology
- Interventional Cardiology
- Vascular Medicine
Background:
- Rotational atherectomy (RA) is a key procedure for treating complex coronary artery disease.
- Ensuring procedural safety and efficacy, particularly regarding complications like slow flow/no-reflow and coronary spasm, is crucial.
- Evaluating novel solutions like heparin rota-flush is essential for optimizing RA outcomes.
Purpose of the Study:
- To assess the feasibility and safety of using heparin rota-flush solution during rotational atherectomy (RA).
- To compare the incidence of slow flow/no-reflow and other complications between heparin rota-flush and traditional rota-flush solutions.
- To determine the optimal flushing strategy for RA procedures.
Main Methods:
- A prospective study involving 200 patients undergoing RA between August 2019 and November 2021.
- Patients were randomized into two groups: heparin rota-flush (n=103) and traditional rota-flush (n=97).
- Primary endpoint: slow flow/no-reflow. Secondary endpoints: procedural success, complications, and major adverse cardiovascular events (MACE).
Main Results:
- No significant difference in slow flow/no-reflow incidence (29.1% vs. 19.6%, P=0.117) or procedural success (97.1% vs. 93.8%, P=0.320) between groups.
- Coronary spasm incidence was significantly higher in the heparin rota-flush group (42.7% vs. 22.7%, P=0.003).
- Severe hypotension and MACE rates were comparable between the groups.
Conclusions:
- Heparin rota-flush solution does not increase slow flow/no-reflow but significantly increases coronary spasm during RA.
- Traditional rota-flush solutions without RotaGlide appear more effective in preventing coronary spasm.
- Routine use of heparin rota-flush solution is not supported for RA procedures based on these findings.

