Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Long-term variability of impulse oscillometry and spirometry in stable COPD and asthma
Jianhua Xu1, Xingxing Sun1, Hanqing Zhu1
1Department of Pulmonary Function Test, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, Shanghai, 200092, China.
Impulse oscillometry (IOS) resistance parameters show good long-term repeatability in stable asthma and chronic obstructive pulmonary disease (COPD). Spirometry shows lower repeatability than IOS resistance parameters across different COPD severity stages.
Area of Science:
- Pulmonary Medicine
- Respiratory Physiology
- Diagnostic Techniques
Background:
- Optimizing spirometry for lung function labs presents challenges.
- Long-term variability between impulse oscillometry (IOS) and spirometry in stable COPD and asthma remains unclear.
- The forced oscillation technique (IOS) is increasingly used in routine lung function testing.
Purpose of the Study:
- To determine the long-term variability of IOS parameters between clinic visits in stable COPD and asthma patients.
- To assess the relationship between IOS parameters' long-term variability and COPD severity.
Main Methods:
- Utilized data from 73 stable COPD and 119 stable asthma patients with at least three clinic visits.
- Calculated standard deviation (SDbv), coefficient of variation (COV), intraclass correlation coefficient (ICC), and coefficient of repeatability (COR).
- Employed statistical tests including Wilcoxon Mann-Whitney, Kruskal Wallis, Bonferroni, Spearman correlation, and multiple regression analyses.
Main Results:
- IOS resistance parameters demonstrated high repeatability (ICC > 0.8) in both COPD and asthma groups, outperforming IOS reactance parameters.
- Spirometry parameters exhibited lower repeatability (ICC < 0.8) compared to IOS resistance parameters, with worsening repeatability in higher GOLD stages of COPD.
- Airflow obstruction severity correlated with the long-term variability of R5 (resistance at 5 Hz) in GOLD 4 COPD patients.
Conclusions:
- IOS resistance parameters offer good long-term repeatability in patients with asthma and COPD.
- Spirometry parameter repeatability is inferior to that of IOS resistance parameters across varying stages of COPD severity.
More Related Videos
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...