Related Experiment Video
Updated: Aug 28, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Utility of Pipeline embolization device for emergency recanalization of a dissecting carotid tonsillar loop:
Yosuke Akamatsu1,2, Santiago Gomez-Paz1, Justin M Moore1
11Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts; and.
Background:
Cervical arterial tortuosity is not uncommon in patients with spontaneous carotid artery dissections (CADs), but the tortuosity often precludes endovascular stent reconstruction. The authors report 2 cases of emergency recanalization of a carotid tonsillar loop dissection using a Pipeline embolization device (PED).
Observations:
Two patients presented with symptomatic CAD involving tonsillar looping of the cervical internal carotid artery (ICA). Although the tonsillar loop prevented navigation of the carotid and peripheral stent delivery system, a PED was easily navigated and successfully deployed, resulting in successful recanalization of a looped ICA.
Lessons:
Emergency recanalization of a cervical CAD using a PED is a feasible alternative for treating a cervical CAD associated with tonsillar loops.