Related Experiment Video
Updated: Aug 28, 2025

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Toward Better Risk Stratification for Implantable Cardioverter-Defibrillator Recipients: Implications of Explainable
Yu Deng1, Sijing Cheng1, Hao Huang1
1The Cardiac Arrhythmia Center, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, No.167 North Lishi Road, Beijing 100037, China.
Abstract:
Background: Current guideline-based implantable cardioverter-defibrillator (ICD) implants fail to meet the demands for precision medicine. Machine learning (ML) designed for survival analysis might facilitate personalized risk stratification. We aimed to develop explainable ML models predicting mortality and the first appropriate shock and compare these to standard Cox proportional hazards (CPH) regression in ICD recipients. Methods and Results: Forty-five routine clinical variables were collected. Four fine-tuned ML approaches (elastic net Cox regression, random survival forests, survival support vector machine, and XGBoost) were applied and compared with the CPH model on the test set using Harrell’s C-index. Of 887 adult patients enrolled, 199 patients died (5.0 per 100 person-years) and 265 first appropriate shocks occurred (12.4 per 100 person-years) during the follow-up. Patients were randomly split into training (75%) and test (25%) sets. Among ML models predicting death, XGBoost achieved the highest accuracy and outperformed the CPH model (C-index: 0.794 vs. 0.760, p < 0.001). For appropriate shock, survival support vector machine showed the highest accuracy, although not statistically different from the CPH model (0.621 vs. 0.611, p = 0.243). The feature contribution of ML models assessed by SHAP values at individual and overall levels was in accordance with established knowledge. Accordingly, a bi-dimensional risk matrix integrating death and shock risk was built. This risk stratification framework further classified patients with different likelihoods of benefiting from ICD implant. Conclusions: Explainable ML models offer a promising tool to identify different risk scenarios in ICD-eligible patients and aid clinical decision making. Further evaluation is needed.
More Related Videos
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
07:31Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Cardiomyopathy V: Interprofessional Care