Related Experiment Video
Updated: Aug 28, 2025

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Concept, hardware development, and clinical trials of a Galinstan based Mercury free sphygmomanometer: Merkfree
Ravinder Kumar1, Mohit Kumar2, Gurpreet Singh Wander3
1Department of Biomedical Engineering, Indian Institute of Technology, Ropar, India. 2018bmz0007@iitrpr.ac.in.
Abstract:
The aim of this work is to develop Merkfree-a mercury-free sphygmomanometer that looks, feels, and operates just like a traditional mercury sphygmomanometer (MS). For this we use Galinstan as a substitute for mercury, which is a non-toxic alloy of Gallium, Indium and Tin. Galinstan is nearly half as dense as mercury and sticks to class. To work with the lower density, we designed an enclosure and scale that is nearly double the length of MS. The issue of stickiness with glass was resolved by maintaining a small meniscus of a reducing agent in the measuring tube and tank of Merkfree. Clinical trials to validate the accuracy of Merkfree against MS and oscillometric sphygmomanometer (OS) were conducted over 252 patients. The results show a good correlation of the systolic and diastolic BP measurements from Merkfree with respect to MS and the OS. The mean absolute percentage error is less than 10% for both SBP and DBP. We also found that Merkfree has lower rounding-off errors compared to MS. Merkfree can be a viable alternative to mercury sphygmomanometer that can help achieve the goal of WHO in eliminating mercury from healthcare, while simultaneously making sure that gold standard technique of sphygmomanometry continues to be available to the clinicians.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure

