Related Experiment Video
Updated: Aug 28, 2025

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
Deep Learning Using Endobronchial-Ultrasound-Guided Transbronchial Needle Aspiration Image to Improve the Overall
Ching-Wei Wang1,2, Muhammad-Adil Khalil2, Yi-Jia Lin3,4
1Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan.
Abstract:
Lung cancer is the biggest cause of cancer-related death worldwide. An accurate nodal staging is critical for the determination of treatment strategy for lung cancer patients. Endobronchial-ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has revolutionized the field of pulmonology and is considered to be extremely sensitive, specific, and secure for lung cancer staging through rapid on-site evaluation (ROSE), but manual visual inspection on the entire slide of EBUS smears is challenging, time consuming, and worse, subjective, on a large interobserver scale. To satisfy ROSE’s needs, a rapid, automated, and accurate diagnosis system using EBUS-TBNA whole-slide images (WSIs) is highly desired to improve diagnosis accuracy and speed, minimize workload and labor costs, and ensure reproducibility. We present a fast, efficient, and fully automatic deep-convolutional-neural-network-based system for advanced lung cancer staging on gigapixel EBUS-TBNA cytological WSIs. Each WSI was converted into a patch-based hierarchical structure and examined by the proposed deep convolutional neural network, generating the segmentation of metastatic lesions in EBUS-TBNA WSIs. To the best of the authors’ knowledge, this is the first research on fully automated enlarged mediastinal lymph node analysis using EBUS-TBNA cytological WSIs. We evaluated the robustness of the proposed framework on a dataset of 122 WSIs, and the proposed method achieved a high precision of 93.4%, sensitivity of 89.8%, DSC of 82.2%, and IoU of 83.2% for the first experiment (37.7% training and 62.3% testing) and a high precision of 91.8 ± 1.2, sensitivity of 96.3 ± 0.8, DSC of 94.0 ± 1.0, and IoU of 88.7 ± 1.8 for the second experiment using a three-fold cross-validation, respectively. Furthermore, the proposed method significantly outperformed the three state-of-the-art baseline models, including U-Net, SegNet, and FCN, in terms of precision, sensitivity, DSC, and Jaccard index, based on Fisher’s least significant difference (LSD) test (p<0.001). For a computational time comparison on a WSI, the proposed method was 2.5 times faster than U-Net, 2.3 times faster than SegNet, and 3.4 times faster than FCN, using a single GeForce GTX 1080 Ti, respectively. With its high precision and sensitivity, the proposed method demonstrated that it manifested the potential to reduce the workload of pathologists in their routine clinical practice.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...

