Multi-Modal Learning-Based Equipment Fault Prediction in the Internet of Things

Xin Nan1, Bo Zhang2, Changyou Liu1

  • 1School of Information Science and Technology, Northwest University, Xi'an 710127, China.

Sensors (Basel, Switzerland)
|September 23, 2022
PubMed

Related Concept Videos

Multi-input and Multi-variable systems01:22

Multi-input and Multi-variable systems

Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence...
143
Machines: Problem Solving I01:22

Machines: Problem Solving I

A toggle clamp is a mechanical device commonly used for holding and clamping objects in various applications, such as woodworking, metalworking, and assembly operations. Consider a toggle clamp subjected to a force of 200 N at the handle. The vertical clamping force can be calculated, provided the dimensions of the toggle clamp are known.
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
396
Machines: Problem Solving II01:30

Machines: Problem Solving II

Machines are complex structures consisting of movable, pin-connected multi-force members that work together to transmit forces. Consider a lifting tong carrying a 100 kg load. It comprises movable sections DAF and CBG linked together with member AB.
355
Distributed Loads: Problem Solving01:21

Distributed Loads: Problem Solving

Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
700
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
118
Machines01:19

Machines

Machines are complex structures consisting of movable, pin-connected multi-force members that work together to transmit forces. One example of a machine is the cutting plier, which is used to cut wires by applying forces to its handles. When equal and opposite forces are exerted on the handles of the cutting plier, they cause the cutting edges to come together and apply equal and opposite reaction forces on the wire, which are greater than the applied forces.
A free-body diagram of the...
321