Related Experiment Video
Updated: Aug 27, 2025

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Evaluating the Typical Day-to-Day Variability of WHOOP-Derived Heart Rate Variability in Olympic Water Polo Athletes
Clint R Bellenger1, Dean Miller2, Shona L Halson3
1Alliance for Research in Exercise, Nutrition and Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide 5000, Australia.
Abstract:
Heart rate (HR) and HR variability (HRV) can be used to infer readiness to perform exercise in athletic populations. Advancements in the photoplethysmography technology of wearable devices such as WHOOP allow for the frequent and convenient measurement of HR and HRV, and therefore enhanced application in athletes. However, it is important that the reliability of such technology is acceptable prior to its application in practical settings. Eleven elite male water polo players (age 28.8 ± 5.3 years [mean ± standard deviation]; height 190.3 ± 3.8 cm; body mass 95.0 ± 6.9 kg; international matches 117.9 ± 92.1) collected their HR and HRV daily via a WHOOP strap (WHOOP 3.0, CB Rank, Boston, MA, USA) over 16 weeks ahead of the 2021 Tokyo Olympic Games. The WHOOP strap quantified HR and HRV via wrist-based photoplethysmography during overnight sleep periods. The weekly (i.e., 7-day) coefficient of variation in lnRMSSD (lnRMSSDCV) and HR (HRCV) was calculated as a measure of day-to-day variability in lnRMSSD and HR, and presented as a mean of the entire recording period. The mean weekly lnRMSSDCV and HRCV over the 16-week period was 5.4 ± 0.7% (mean ± 95% confidence intervals) and 7.6 ± 1.3%, respectively. The day-to-day variability in WHOOP-derived lnRMSSD and HR is within or below the range of day-to-day variability in alternative lnRMSSD (~3-13%) and HR (~10-11%) assessment protocols, indicating that the assessment of HR and HRV by WHOOP does not introduce any more variability than that which is naturally present in these variables.
More Related Videos
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
05:48Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Body Water Content and Fluid Compartments