Discriminative Method for Crack Detection Signals in Balanced-Field Electromagnetic Technique Based on
Jiayin Li1, Lijian Yang1, Wenxue Zheng1
1School of Information Science and Engineering, Shenyang University of Technology, Shenyang 110870, China.
Abstract:
The balanced-field electromagnetic technique is an effective in-line inspection method for pipeline cracks. To address the problem that the interference signal generated by the tilt jitter of the sensor during the detection process affects the judgment of cracks, this paper proposes a method to differentiate the crack detection signal from the sensor jitter signal by using an amplitude-phase composite figure. The generation principle of the detection signal was analyzed by using the mutual inductance model, and the amplitude-phase composite figure was constructed by using the components of the detection signal after quadrature demodulation. The feasibility of using the phase as a signal discrimination feature was illustrated by finite element simulations, and the characteristics of the amplitude-phase composite figure were determined. The validity of the proposed method was verified experimentally. The results show that the crack detection signal and the signal generated by the sensor jitter are of the same frequency with similar waveforms and significantly different phases. The phase base value of the crack detection signal ranges from 35° to 55°, and the phase base value of the jitter signal is -4°. In terms of the characteristics of the amplitude-phase composite figure, the crack detection signal distribution is symmetrical about the origin in the first and third quadrants, and the axial crack is closer to the Y-axis than the circumferential crack; the jitter signal is distributed in the second and fourth quadrants and has a very small angle to the X-axis. In addition, the proposed method effectively weakens the observation of the phase noise region in the detection signal of the balanced-field electromagnetic technique.
More Related Videos
07:42Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
Published on: July 20, 2022
09:38Fabrication Procedures and Birefringence Measurements for Designing Magnetically Responsive Lanthanide Ion Chelating Phospholipid Assemblies
Published on: January 3, 2018
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
The Hall Effect
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Instrumentation
Gas Chromatography: Types of Detectors-II