Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Multifrequency bioimpedance by spectroscopy vs. routine methods in the management of hydration status in peritoneal
Fabiana Lourenço Costa1, Nayrana Soares do Carmo Reis1, Fabricio Moreira Reis1
1Department Internal Medicine, Botucatu Medical School, São Paulo State University, Botucatu, Brazil.
Background:
Overhydration (OH) is common in peritoneal dialysis (PD) and increases the cardiovascular risk. Multifrequency bioimpedance spectroscopy (BIS) has been proposed to estimate the hydration in dialysis. Our objective was to evaluate if BIS is superior than control based on clinical assessment plus single-frequency bioimpedance (SF-BIA) on the fluid control and intermediate cardiovascular outcomes.
Methods:
Randomized controlled study in adult PD patients, with a 9-month follow-up, allocated into two groups: control and BIS. Data were collected from medical records. SF-BIA and BIS, laboratory exams, ambulatory blood pressure monitoring, echocardiography (ECHO), and pulse wave velocity (PWV) were evaluated. The BIS data were available to the medical team only in BIS group.
Results:
34 patients completed the study, 17 in each group. At the endpoint the BIS group had a significant (p < 0.05) greater proportion of patients with OH/extracellular water (OH/ECW%) ≤ 15% than the control (94.1% vs. 52.9%), and a lower OH mean (2.1 ± 1.6 vs. 0.9 ± 1.1 L). The control group has a significant increase in the tumor necrosis factor alpha median concentration from baseline to six [11.9 (6.0-24.1) vs. 44.7 (9.4-70.6) pg/ml] and 9 months [11.9 (6.0-24.1) vs. 39.4 (27.9-62.6) pg/ml], and in the N-terminal fragment of pro-B-type natriuretic peptide median [239 (171.5-360.5) vs. 356 (219-1,555) pg/ml]. For cardiovascular parameters, BIS group presented a significant reduction in radial PWV [7.7 (6.9-9.2) vs. 6.5 (5.5-8.4) m/s] at 9 month, while in the control presented a significant increase in mean central systolic blood pressure (BP) (106.8 ± 11.2 vs. 117.6 ± 16.5 mmHg) and in central diastolic BP (90.4 ± 9.8 vs. 103.3 ± 12.5 mmHg) at 9 months. The left ventricular mass (LVM)/body surface presented a significant reduction in the control (109.6 ± 30.8 vs. 101.2 ± 28.9 g/m2) and BIS group (107.7 ± 24.9 vs. 96.1 ± 27.0 g/m2) at 9 months.
Conclusion:
The results suggest BIS is superior than the clinical evaluation plus SF-BIA for the fluid control of PD patients.
Clinical Trial Registration:
[https://www.ClinicalTrials.gov], identifier [RBR-10k8j3bx].
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
Related Concept Videos
Dialysis
Peritoneal Dialysis III: Nursing Management
Peritoneal Dialysis I: Introduction and Procedure
Hemodialysis III: Nursing Management
Acute Kidney Injury V: Interprofessional Care
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications