Breast Shielding Combined With an Optimized Computed Tomography Pulmonary Angiography Pregnancy Protocol: A Special
Ciara D Gillespie1, Andrew Yates1, Mark C Murphy1
1Departments of Radiology.
Objectives:
To determine the impact of breast shields on breast dose and image quality when combined with a low-dose computed tomography pulmonary angiography (CTPA) protocol for pregnancy.
Methods:
A low-dose CTPA protocol, with and without breast shields, was evaluated by anthropomorphic phantom and 20 prospectively recruited pregnant participants from January to October 2019. Thermoluminescent dosimeters measured surface and absorbed breast dose in the phantom and surface breast dose in participants. The Monte-Carlo method estimated the absorbed breast dose in participants. Image quality was assessed quantitatively by regions of interest analysis and subjectively by the Likert scale. Doses and image quality for CTPA alone were compared with CTPA with breast shields.
Results:
Mean surface and absorbed breast dose for CTPA alone were 1.3±0.4 and 2.8±1.5 mGy in participants, and 1.5±0.7 and 1.6±0.6 mGy in the phantom. Shielding reduced surface breast dose to 0.5±0.3 and 0.7±0.2 mGy in the phantom (66%) and study participants (48%), respectively. Absorbed breast dose reduced to 0.9±0.5 mGy (46%) in the phantom.Noise increased with breast shields at lower kV settings (80 to 100 kV) in the phantom; however, in study participants there was no significant difference between shield and no-shield groups for main pulmonary artery noise (no-shield: 34±9.8, shield: 36.3±7.2, P =0.56), SNR (no-shield: 11.2±3.7, shield: 10.8±2.6, P =0.74) or contrast-to-noise ratio (no-shield: 10.0±3.3, shield: 9.3±2.4, P =0.6). Median subjective image quality scores were comparable (no-shield: 4.0, interquartile range: 3.5 to 4.4, shield: 4.3, interquartile range: 4.0 to 4.5).
Conclusion:
Combining low-dose CTPA with breast shields confers additional breast-dose savings without impacting image quality and yields breast doses approaching those of low-dose scintigraphy, suggesting breast shields play a role in protocol optimization for select groups.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...