Systematic active environmental surveillance successfully identified and controlled the Legionella contamination in
Junya Nakade1, Yoko Nakamura2, Yusuke Katayama3
1Department of Infection Control and Prevention, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan; Department of Hospital Pharmacy, University Hospital, Kanazawa University, Kanazawa, Ishikawa, Japan.
Introduction:
Legionella disease can manifest as severe respiratory tract infection with a high mortality rate and is sometimes associated with a hospital outbreak by a contaminated water supply. A patient with breast cancer admitted about a month before. High fever was observed 18 days after admission and the Legionella antigen test showed the positive result.
Methods:
Due to the incidence of Legionella infection, we demonstrated the active surveillance of Legionella contamination in the entire hospital.
Results:
Cultures of her environmental samples revealed that hot water in two bathrooms were contaminated with Legionella. In our hospital, the hot water is heated and pumped up on the roof and distributed to each room. The contaminated bathrooms were related to the same plumbing. Therefore, we further collected samples throughout the hot water system. Legionella was not detected in the central part of the system. However, we detected Legionella in the hot water sampled from other five rooms, which were also associated with the same plumbing of the two bathrooms. The temperature and chlorine concentration of the hot water were not high enough to inactivate Legionella at the end of the plumbing. After the adjustment of the water temperature and chlorine concentration, Legionella became undetectable. Our prompt and active surveillance successfully identified the plumbing of the hot water system as the source of Legionella contamination and took precautions against future outbreaks.
Conclusions:
Monitoring of water temperature and chloride concentration at the end of the hot water circulation is important to prevent nosocomial Legionella disease.
More Related Videos
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Methods for Controlling Microbial Growth
Infection
The chain begins with pathogens: bacteria, viruses, fungi, prions, or parasites such as protozoa helminths. These can be present on the skin as transient or resident flora, or they can be acquired from the environment. Identifying and treating the type of infection and...