Identification of arterial oxygen intermittency in oximetry data
Paulo P Galuzio1, Alhaji Cherif2, Xia Tao3
1Research Division, Renal Research Institute, New York, NY, USA. paulo.galuzio@rriny.com.
Abstract:
In patients with kidney failure treated by hemodialysis, intradialytic arterial oxygen saturation (SaO2) time series present intermittent high-frequency high-amplitude oximetry patterns (IHHOP), which correlate with observed sleep-associated breathing disturbances. A new method for identifying such intermittent patterns is proposed. The method is based on the analysis of recurrence in the time series through the quantification of an optimal recurrence threshold ([Formula: see text]). New time series for the value of [Formula: see text] were constructed using a rolling window scheme, which allowed for real-time identification of the occurrence of IHHOPs. The results for the optimal recurrence threshold were confronted with standard metrics used in studies of obstructive sleep apnea, namely the oxygen desaturation index (ODI) and oxygen desaturation density (ODD). A high correlation between [Formula: see text] and the ODD was observed. Using the value of the ODI as a surrogate to the apnea-hypopnea index (AHI), it was shown that the value of [Formula: see text] distinguishes occurrences of sleep apnea with great accuracy. When subjected to binary classifiers, this newly proposed metric has great power for predicting the occurrences of sleep apnea-related events, as can be seen by the larger than 0.90 AUC observed in the ROC curve. Therefore, the optimal threshold [Formula: see text] from recurrence analysis can be used as a metric to quantify the occurrence of abnormal behaviors in the arterial oxygen saturation time series.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
04:10Author Spotlight: Exploring Venous Waveforms for Non-Invasive Respiratory Monitoring in Pigs
Published on: March 8, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: