Related Experiment Video
Updated: Aug 27, 2025

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications
Haya Jamali1, Lauren T Castillo2, Chelsea Cosby Morgan3
1Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts.
Abstract:
The pulse oximeter is a ubiquitous clinical tool used to estimate blood oxygen concentrations. However, decreased accuracy of pulse oximetry in patients with dark skin tones has been demonstrated since as early as 1985. Most commonly, pulse oximeters may overestimate the true oxygen saturation in individuals with dark skin tones, leading to higher rates of occult hypoxemia (i.e., clinically unrecognized low blood oxygen saturation). Overestimation of oxygen saturation in patients with dark skin tones has serious clinical implications, as these patients may receive insufficiently rigorous medical care when pulse oximeter measurements suggest that their oxygen saturation is higher than the true value. Recent studies have linked pulse oximeter inaccuracy to worse clinical outcomes, suggesting that pulse oximeter inaccuracy contributes to known racial health disparities. The magnitude of device inaccuracy varies by pulse oximeter manufacturer, sensor type, and arterial oxygen saturation. The underlying reasons for decreased pulse oximeter accuracy for individuals with dark skin tones may be related to failure to control for increased absorption of red light by melanin during device development and insufficient inclusion of individuals with dark skin tones during device calibration. Inadequate regulatory standards for device approval may also play a role in decreased accuracy. Awareness of potential pulse oximeter limitations is an important step for providers and may encourage the consideration of additional clinical information for management decisions. Ultimately, stricter regulatory requirements for oximeter approval and increased manufacturer transparency regarding device performance are required to mitigate this racial bias.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Transport in the Blood