Related Experiment Video
Updated: Aug 27, 2025

06:51
Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
7.6K
Accuracy of Impression Techniques for Dental Implants Placed in Five Different Orientations
The International Journal of Oral & Maxillofacial Implants
|September 28, 2022
Summary
Dental implant impression accuracy is highest with parallel placement. The dual-arch technique showed lower accuracy than the open-tray technique when implants were angled, especially at 30 degrees.
Area of Science:
- Dental Implantology
- Prosthodontics
- Biomaterials
Background:
- Accurate dental implant impressions are crucial for successful prosthetic restorations.
- Evaluating different impression techniques and implant angulations is essential for optimizing clinical outcomes.
Purpose of the Study:
- To assess the impression accuracy of two implants in various orientations.
- To compare the dual-arch impression technique with hybrid copings against the conventional open-tray technique.
Main Methods:
- Five mandibular models with implants in varying parallel and angled (15- and 30-degree) orientations were used.
- Impressions were made using both open-tray and dual-arch techniques (n=10 per model).
- Three-dimensional deviations were calculated by scanning cast models and comparing them to original models.
Main Results:
- The greatest deviations occurred with 30-degree mesiodistal angulation for both techniques.
- The dual-arch technique demonstrated significantly lower accuracy than the open-tray technique for 15- and 30-degree mesiodistal, and 30-degree buccolingual angulations.
- No significant difference in accuracy was found between the techniques for parallel implants.
Conclusions:
- Thirty-degree mesiodistal implant angulation resulted in the largest deviations for both impression techniques.
- The dual-arch technique exhibited reduced accuracy compared to the open-tray technique with increased implant angulation.
- Parallel implant placement appears to enhance impression accuracy and may allow for the use of the dual-arch technique.