Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry SESI-MS
Published on: June 8, 2011
Implementing reactive secondary electrospray ionization based on gas-droplet reactions for VOC analysis
Quan Yu1, Jing Gao1, Xiaohua Yu2
1Division of Advanced Manufacturing, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China. yu.quan@sz.tsinghua.edu.cn.
Abstract:
Gas-droplet reactions occur at the microdroplet interface and tend to be greatly accelerated, which has great potential value in chemical analysis. To exploit such value, we combined online derivatization with secondary electrospray ionization (SESI) to implement a special ionization technique, termed reactive SESI, for rapid analysis of gas samples. Specifically, a suitable reagent was added to the spray solvent of SESI to initiate rapid derivatization of gas analytes in the microdroplets. The product ions are subsequently detected using a mass spectrometer. Compared to offline derivatization in bulk solution, reactive SESI can provide a higher yield and a faster reaction rate, and it allows the detection of intermediate ions. It is found that the signal changes of the analyte, intermediate, and product ions are highly consistent, indicating that a two-phase derivatization process may occur at the droplet interface. For reactive SESI-MS analysis, the use of a sub-ambient pressure SESI source can significantly improve the detection efficiency, making this technique truly useful for analytical applications, including the quantification of formaldehyde at tens of ppb levels in air, as well as the detection of various trace VOCs in exhaled breath from mice.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography: Types of Detectors-II
Chemical Ionization (CI) Mass Spectrometry