Abstract:
Arterial blood oxygen saturation as measured by pulse oximetry (peripheral oxygen saturation (SpO2)) may be differentially less accurate for people with darker skin pigmentation, which could potentially affect the course of coronavirus disease 2019 (COVID-19) treatment. We analyzed pulse oximeter accuracy and its association with COVID-19 treatment outcomes using electronic health record data from Sutter Health, a large, mixed-payer, integrated health-care delivery system in Northern California. We analyzed 2 cohorts: 1) 43,753 non-Hispanic White (NHW) or non-Hispanic Black/African-American (NHB) adults with concurrent arterial blood gas oxygen saturation/SpO2 measurements taken between January 2020 and February 2021; and 2) 8,735 adults who went to a hospital emergency department with COVID-19 between July 2020 and February 2021. Pulse oximetry systematically overestimated blood oxygenation by 1% more in NHB individuals than in NHW individuals. For people with COVID-19, this was associated with lower admission probability (-3.1 percentage points), dexamethasone treatment (-3.1 percentage points), and supplemental oxygen treatment (-4.5 percentage points), as well as increased time to treatment: 37.2 minutes before dexamethasone initiation and 278.5 minutes before initiation of supplemental oxygen. These results call for additional investigation of pulse oximeters and suggest that current guidelines for development, testing, and calibration of these devices should be revisited, investigated, and revised.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...