[Design and application of an extension tube for ventilator pipeline]
Yawei Jiang1, Jian Wang2, Wenwen Zhao3
1Department of Critical Care Medicine, the Eighth Medical Center of People's Liberation Army General Hospital, Beijing 100091, China.
Abstract:
At present, the extension tube of the ventilator, a long corrugated tube used in clinical practice, needs to be disconnected from the endotracheal tube when performing open sputum suction. Under positive pressure, the condensed water containing pathogenic microorganisms in the ventilator will be splashed. Some will form aerosol suspended in the air, pollute the air, increase the risk of cross-infection and operator pollution, while the ventilator will emit a corresponding alarm sound, resulting in noise pollution. Based on the above factors, a ventilator pipeline extension tube was designed by the medical staff of department of critical care medicine of the Eighth Medical Center of People's Liberation Army General Hospital and department of critical care medicine of Beijing Friendship Hospital of Capital Medical University, and was obtained the National Utility Model Patent of China (ZL 2020 2 1476518.X). The device consists of the main pipe, first pipe sleeve, second pipe sleeve, valve body, joystick, axial sleeve, etc., which can not only effectively avoid air pollution and reduce the risk of cross-infection, but also reduce noise pollution and the negative impact of loud noise on patients and medical staff.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...