Related Experiment Video
Updated: Aug 27, 2025

High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
SWAVE 2.0 Imaging of Placental Elasticity and Viscosity: Potential Biomarkers for Placenta-Mediated Disease Detection
Farah Deeba1, Ricky Hu1, Victoria Lessoway2
1Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada.
Pregnancy complications such as pre-eclampsia (PE) and intrauterine growth restriction (IUGR) are associated with structural and functional changes in the placenta. Different elastography techniques with an ability to assess the mechanical properties of tissue can identify and monitor the pathological state of the placenta. Currently available elastography techniques have been used with promising results to detect placenta abnormalities; however, limitations include inadequate measurement depth and safety concerns from high negative pressure pulses. Previously, we described a shear wave absolute vibro-elastography (SWAVE) method by applying external low-frequency mechanical vibrations to generate shear waves and studied 61 post-delivery clinically normal placentas to explore the feasibility of SWAVE for placental assessment and establish a measurement baseline. This next phase of the study, namely, SWAVE 2.0, improves the previous system and elasticity reconstruction by incorporating a multi-frequency acquisition system and using a 3-D local frequency estimation (LFE) method. Compared with its 2-D counterpart, the proposed system using 3-D LFE was found to reduce the bias and variance in elasticity measurements in tissue-mimicking phantoms. In the aim of investigating the potential of improved SWAVE 2.0 measurements to identify placental abnormalities, we studied 46 post-delivery placentas, including 26 diseased (16 IUGR and 10 PE) and 20 normal control placentas. By use of a 3.33-MHz motorized curved-array transducer, multi-frequency (80,100 and 120 Hz) elasticity measures were obtained with 3-D LFE, and both IUGR (15.30 ± 2.96 kPa, p = 3.35e-5) and PE (12.33 ± 4.88 kPa, p = 0.017) placentas were found to be significantly stiffer compared with the control placentas (8.32 ± 3.67 kPa). A linear discriminant analysis (LDA) classifier was able to classify between healthy and diseased placentas with a sensitivity, specificity and accuracy of 87%, 78% and 83% and an area under the receiver operating curve of 0.90 (95% confidence interval: 0.8-0.99). Further, the pregnancy outcome in terms of neonatal intensive care unit admission was predicted with a sensitivity, specificity and accuracy of 70%, 71%, 71%, respectively, and area under the receiver operating curve of 0.78 (confidence interval: 0.62-0.93). A viscoelastic characterization of placentas using a fractional rheological model revealed that the viscosity measures in terms of viscosity parameter n were significantly higher in IUGR (2.3 ± 0.21) and PE (2.11 ± 0.52) placentas than in normal placentas (1.45 ± 0.65). This work illustrates the potential relevance of elasticity and viscosity imaging using SWAVE 2.0 as a non-invasive technology for detection of placental abnormalities and the prediction of pregnancy outcomes.
Pregnancy complications such as pre-eclampsia (PE) and intrauterine growth restriction (IUGR) are associated with structural and functional changes in the placenta. Different elastography techniques with an ability to assess the mechanical properties of tissue can identify and monitor the pathological state of the placenta. Currently available elastography techniques have been used with promising results to detect placenta abnormalities; however, limitations include inadequate measurement depth and safety concerns from high negative pressure pulses. Previously, we described a shear wave absolute vibro-elastography (SWAVE) method by applying external low-frequency mechanical vibrations to generate shear waves and studied 61 post-delivery clinically normal placentas to explore the feasibility of SWAVE for placental assessment and establish a measurement baseline. This next phase of the study, namely, SWAVE 2.0, improves the previous system and elasticity reconstruction by incorporating a multi-frequency acquisition system and using a 3-D local frequency estimation (LFE) method. Compared with its 2-D counterpart, the proposed system using 3-D LFE was found to reduce the bias and variance in elasticity measurements in tissue-mimicking phantoms. In the aim of investigating the potential of improved SWAVE 2.0 measurements to identify placental abnormalities, we studied 46 post-delivery placentas, including 26 diseased (16 IUGR and 10 PE) and 20 normal control placentas. By use of a 3.33-MHz motorized curved-array transducer, multi-frequency (80,100 and 120 Hz) elasticity measures were obtained with 3-D LFE, and both IUGR (15.30 ± 2.96 kPa, p = 3.35e-5) and PE (12.33 ± 4.88 kPa, p = 0.017) placentas were found to be significantly stiffer compared with the control placentas (8.32 ± 3.67 kPa). A linear discriminant analysis (LDA) classifier was able to classify between healthy and diseased placentas with a sensitivity, specificity and accuracy of 87%, 78% and 83% and an area under the receiver operating curve of 0.90 (95% confidence interval: 0.8-0.99). Further, the pregnancy outcome in terms of neonatal intensive care unit admission was predicted with a sensitivity, specificity and accuracy of 70%, 71%, 71%, respectively, and area under the receiver operating curve of 0.78 (confidence interval: 0.62-0.93). A viscoelastic characterization of placentas using a fractional rheological model revealed that the viscosity measures in terms of viscosity parameter n were significantly higher in IUGR (2.3 ± 0.21) and PE (2.11 ± 0.52) placentas than in normal placentas (1.45 ± 0.65). This work illustrates the potential relevance of elasticity and viscosity imaging using SWAVE 2.0 as a non-invasive technology for detection of placental abnormalities and the prediction of pregnancy outcomes.
More Related Videos
09:33Three-dimensional Rendering and Analysis of Immunolabeled, Clarified Human Placental Villous Vascular Networks
Published on: March 29, 2018
09:04Comprehensive Evaluation of the Effectiveness and Safety of Placenta-Targeted Drug Delivery Using Three Complementary Methods
Published on: September 10, 2018
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies VII: Vascular Imaging
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: