SWAVE 2.0 Imaging of Placental Elasticity and Viscosity: Potential Biomarkers for Placenta-Mediated Disease Detection

Farah Deeba1, Ricky Hu1, Victoria Lessoway2

  • 1Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada.

Pregnancy complications such as pre-eclampsia (PE) and intrauterine growth restriction (IUGR) are associated with structural and functional changes in the placenta. Different elastography techniques with an ability to assess the mechanical properties of tissue can identify and monitor the pathological state of the placenta. Currently available elastography techniques have been used with promising results to detect placenta abnormalities; however, limitations include inadequate measurement depth and safety concerns from high negative pressure pulses. Previously, we described a shear wave absolute vibro-elastography (SWAVE) method by applying external low-frequency mechanical vibrations to generate shear waves and studied 61 post-delivery clinically normal placentas to explore the feasibility of SWAVE for placental assessment and establish a measurement baseline. This next phase of the study, namely, SWAVE 2.0, improves the previous system and elasticity reconstruction by incorporating a multi-frequency acquisition system and using a 3-D local frequency estimation (LFE) method. Compared with its 2-D counterpart, the proposed system using 3-D LFE was found to reduce the bias and variance in elasticity measurements in tissue-mimicking phantoms. In the aim of investigating the potential of improved SWAVE 2.0 measurements to identify placental abnormalities, we studied 46 post-delivery placentas, including 26 diseased (16 IUGR and 10 PE) and 20 normal control placentas. By use of a 3.33-MHz motorized curved-array transducer, multi-frequency (80,100 and 120 Hz) elasticity measures were obtained with 3-D LFE, and both IUGR (15.30 ± 2.96 kPa, p = 3.35e-5) and PE (12.33 ± 4.88 kPa, p = 0.017) placentas were found to be significantly stiffer compared with the control placentas (8.32 ± 3.67 kPa). A linear discriminant analysis (LDA) classifier was able to classify between healthy and diseased placentas with a sensitivity, specificity and accuracy of 87%, 78% and 83% and an area under the receiver operating curve of 0.90 (95% confidence interval: 0.8-0.99). Further, the pregnancy outcome in terms of neonatal intensive care unit admission was predicted with a sensitivity, specificity and accuracy of 70%, 71%, 71%, respectively, and area under the receiver operating curve of 0.78 (confidence interval: 0.62-0.93). A viscoelastic characterization of placentas using a fractional rheological model revealed that the viscosity measures in terms of viscosity parameter n were significantly higher in IUGR (2.3 ± 0.21) and PE (2.11 ± 0.52) placentas than in normal placentas (1.45 ± 0.65). This work illustrates the potential relevance of elasticity and viscosity imaging using SWAVE 2.0 as a non-invasive technology for detection of placental abnormalities and the prediction of pregnancy outcomes.

Related Concept Videos

Imaging Studies II: Ultrasonography01:24

Imaging Studies II: Ultrasonography

IntroductionUltrasonography, or renal ultrasound, is a noninvasive medical imaging technique that uses high-frequency sound waves to visualize the kidneys, ureters, bladder, and surrounding tissues.Indications for Urinary System UltrasonographyUrinary system ultrasonography is indicated in various clinical scenarios, such as:Kidney Stones (Urolithiasis): To detect and monitor the size and presence of kidney or urinary tract stones.Hydronephrosis: To assess the dilation of the renal pelvis and...
41
Ultrasonography01:17

Ultrasonography

Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
4.8K
Imaging Studies VII: Vascular Imaging01:19

Imaging Studies VII: Vascular Imaging

DefinitionRenal angiography, also known as renal arteriography, is an imaging technique used to obtain a comprehensive view of blood flow and the vascular structure of blood vessels in the kidneys and surrounding areas.PurposeRenal angiography detects blood vessel abnormalities in the kidneys, such as aneurysms, stenosis, thrombosis, vascular tumors, and renal artery stenosis. It evaluates kidney function and guides interventional treatments like angioplasty or stent placement.Pre-Procedure...
48
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.6K