Related Experiment Video
Updated: Aug 27, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Increased tissue water in patients with severe sepsis affects tissue oxygenation measured by near-infrared
Chin-Kuo Lin1,2, Shaw-Woei Leu3, Ying-Huang Tsai4,5
1Department of Pulmonary and Critical Care Medicine, Chang Gung Memorial Hospital, Chiayi.
Background:
Tissue oedema affects tissue perfusion and interferes with the monitoring of tissue oxygenation in patients with severe sepsis. However, the underlying mechanisms remain unclear. We used a wireless near-infrared spectroscopy (NIRS) device that transmits tri-wavelength light to quantify tissue haemoglobin (Hb) and water (H2O) content. We estimated tissue H2O in severe sepsis patients and healthy controls, compared their difference, and investigated the correlation of tissue H2O with systemic haemodynamics and its impact on tissue oxygenation.
Methods:
Seventy-seven adult patients with new-onset severe sepsis admitted to the intensive care unit within 72 h and 30 healthy volunteers (controls) were enrolled. The NIRS device was placed on the participant's leg to estimate the relative tissue concentrations of oxy-Hb ([HbO), deoxy-Hb ([HbR]), total Hb ([HbT]), and H2O ([H) at rest for three consecutive days. Two-sample t-test or Mann-Whitney U test, chi-square test, and generalised estimating equations (GEEs) were used for comparisons.
Results:
In severe sepsis patients, the [H in the anterior tibia was higher [mean (standard deviation, 95% confidence interval), 10.57 (3.37, 9.81-11.34) vs. 7.40 (1.89, 6.70-8.11)] and the [HbO, [HbT], and tissue Hb oxygen saturation (StO2) were lower [0.20 (0.01, 0.20-0.20) vs. 0.22 (0.01, 0.22-0.23), 0.42 (0.02, 0.42-0.43) vs. 0.44 (0.02, 0.44-0.45), and 47.25% (1.97%, 46.80-47.70%) vs. 49.88% (1.26%, 49.41-50.35%), respectively] than in healthy controls in first-day measurements. GEE analysis revealed significant differences in [H, [HbO, [HbT], and StO2 between groups over three consecutive days (all P≤0.001). In addition, [HbO and StO2 levels gradually decreased over time in the patient group. A negative correlation was observed between [H and [HbO and StO2, which became more obvious over time (day 1: r=-0.51 and r=-0.42, respectively; both P<0.01; day 3: r=-0.67 and r=-0.63, respectively, both P<0.01). Systolic arterial pressure was positively related to [H (r=0.51, P<0.05, on day 1) but was not associated with tissue oxygenation parameters.
Conclusions:
NIRS can be used to quantify tissue H2O. Severe sepsis patients have increased tissue H2O, which responds to changes in arterial blood pressure and affects tissue oxygenation.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...