A solution for co-frequency and low SNR problems in heart rate estimation based on photoplethysmography signals
Jiaqi Zhao1, Xiang Chen2, Xu Zhang1
1Dept Elect Sci & Technol, University of Science and Technology of China, Hefei, 230027, Anhui, China.
Abstract:
In order to realize high-accuracy heart rate (HR) estimation based on photoplethysmography (PPG) under the scenes of low signal-to-noise ratio (SNR) and co-frequency caused by motion artifacts (MAs), this paper presents a novel framework integrating two-stage variational mode decomposition (VMD) denoising method, noise compensation technology, and hidden Markov model (HMM)-based tracking algorithm. The two-stage VMD denoising method is designed to separate the HR signal from MA under low SNR scene. The noise compensation technology is applied to solve the problem of co-frequency. HMM-based HR tracking method is adopted to obtain the global optimization performance of HR estimation. The effectiveness and superiority of the proposed framework in solving problems of low SNR and co-frequency associated with motion artifacts have been verified by the HR estimation experiments carried out on three public high-SNR PPG databases (ISPC, BAMI I, BAMI II) and a self-built low-SNR database (WeData). Compared with the two classical frameworks namely joint sparse spectrum reconstruction (JOSS) and convolutional neural network-long short-term memory network (CNN-LSTM), the proposed framework obtains the lowest HR estimation errors (0.94 beats per minute (BPM) and 1.81 BPM respectively) on both BAMI 2 with the highest SNR (0.40 dB) and WeData with the lowest SNR (- 9.07 dB). For the low-SNR database Wedata, the average absolute error (AAE) decreases by more than 21 BPM. The research result of this study provides a solution for the realization of high-accuracy PPG-based HR estimation in exercise scenarios.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...