Demonstration and Performance Evaluation of Two Novel Algorithms for Removing Artifacts From Automated Intraoperative
Amit Bardia1, Ranjit Deshpande2, George Michel2
1Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, United States.
Background:
The automated acquisition of intraoperative patient temperature data via temperature probes leads to the possibility of producing a number of artifacts related to probe positioning that may impact these probes' utility for observational research.
Objective:
We sought to compare the performance of two de novo algorithms for filtering such artifacts.
Methods:
In this observational retrospective study, the intraoperative temperature data of adults who received general anesthesia for noncardiac surgery were extracted from the Multicenter Perioperative Outcomes Group registry. Two algorithms were developed and then compared to the reference standard-anesthesiologists' manual artifact detection process. Algorithm 1 (a slope-based algorithm) was based on the linear curve fit of 3 adjacent temperature data points. Algorithm 2 (an interval-based algorithm) assessed for time gaps between contiguous temperature recordings. Sensitivity and specificity values for artifact detection were calculated for each algorithm, as were mean temperatures and areas under the curve for hypothermia (temperatures below 36 C) for each patient, after artifact removal via each methodology.
Results:
A total of 27,683 temperature readings from 200 anesthetic records were analyzed. The overall agreement among the anesthesiologists was 92.1%. Both algorithms had high specificity but moderate sensitivity (specificity: 99.02% for algorithm 1 vs 99.54% for algorithm 2; sensitivity: 49.13% for algorithm 1 vs 37.72% for algorithm 2; F-score: 0.65 for algorithm 1 vs 0.55 for algorithm 2). The areas under the curve for time × hypothermic temperature and the mean temperatures recorded for each case after artifact removal were similar between the algorithms and the anesthesiologists.
Conclusions:
The tested algorithms provide an automated way to filter intraoperative temperature artifacts that closely approximates manual sorting by anesthesiologists. Our study provides evidence demonstrating the efficacy of highly generalizable artifact reduction algorithms that can be readily used by observational studies that rely on automated intraoperative data acquisition.
More Related Videos
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
07:46Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...