Carbon-polymer dot-based UV absorption and fluorescence performances for heavy metal ion detection
Jiemin Qiu1, Danhong Zeng1, Yichun Lin1
1Key Laboratory for Biobased Materials and Energy of Ministry of Education/Guangdong Provincial Engineering Technology Research Center for Optical Agriculture, College of Materials and Energy, South China Agricultural University, Guangzhou 510642, China.
Abstract:
In previous reports, carbon dots (CDs) were customarily used as fluorescent probes to detect heavy metal ions. However, scientists neglected to take advantage of the excellent UV absorption properties of CDs to detect heavy metal ions. Herein, we synthesized nitrogen-containing carbon polymer dots (N-CPDs) for the determination of Co2+ ions in water samples by a one-step hydrothermal method using l-histidine and ethylene imine polymer as raw materials. The N-CPDs were characterized by ultraviolet-visible spectrum (UV-vis), infrared spectrum (FT-IR), X-ray photoelectron spectrum (XPS) and transmission electron microscopy (TEM) techniques. They possess superior full-band UV absorption performance and the surface is rich in multifunctional groups such as -COOH, -CN-, -OH, etc. When Co2+ was added to N-CPDs solution, the color of the solution rapidly changed from colorless to yellow-brown, which was visible to the naked eye. The UV absorption intensity of N-CPDs changed, and the fluorescence was instantly quenched, due to the formation of chelate between Co2+ and N-CPDs, and the FRET process occurred. The detection of Co2+ showed good linearity for both fluorescence and UV absorption spectroscopy modes in the range of 0-200 μM, and the limit of detection were 1.0023 μM and 0.75 μM, respectively. These two methods have the advantages of simple operation, remarkable selectivity and small sample size, which can be applied to the field detection of Co2+ in water samples. It is possible to develop the UV absorption properties of CDs to detect the ions.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Photoluminescence: Applications
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...