X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Evaluation of AEC Consistency in Digital X-ray Imaging Systems]
Hiroki Saito1, Ayaka Maruyama2, Hiroyuki Miyake2
1Department of Radiology, Toyo Public Health College.
Abstract:
The Japan Network for Research and Information on Medical Exposures (J-RIME) established the diagnostic reference level (DRL) and is advancing optimization of radiation protection. We believe that the difference in the imaging dose between facilities may be due to the fact that automatic exposure control (AEC) adjustment is not unified among manufacturers. The consistency of AEC is specified in JIS 4751-2-54, but it is not applicable to digital X-ray imaging systems because it is for optical density of analog X-ray imaging systems. This article evaluates the consistency of AEC in digital X-ray imaging systems. The AEC consistency was compared with the AEC-estimated dose from the air kerma (KAEC) using the phosphor-based imaging plate placed at the back of the AEC detector. We measured the AEC tube voltage and subject thickness characteristics (tracking) of four types of digital X-ray imaging systems at three facilities. In the test of tube voltage characteristics, the average KAEC values at all tube voltages were 2.37±0.04 µGy for A system, 7.30±1.44 µGy for B system, 3.53±0.13 µGy for C system, and 5.70±0.18 µGy for D system. The relative errors were +2.6 to -1.8% for A system, +25.3 to -22.6% for B system, +5.2 to -1.4% for C system, and +2.5 to -4.4% for D system. In the subject thickness characteristics test, the average KAEC values for all Al thicknesses were 2.34±0.02 µGy for A system, 5.95±0.23 µGy for B system, 4.25±1.12 µGy for C system, and 5.03±1.27 µGy for D system. The relative errors were +1.0 to -0.9% for A system, +4.1 to -5.0% for B system, +40.5 to -28.1% for C system, and +19.7 to -42.9% for D system.
More Related Videos
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...