Related Experiment Video
Updated: Aug 26, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma
Di Chen1, Xiu-Juan Guo2, Shu-Ke Luo1
1Department of Ophthalmology, Affiliated Foshan Hospital, Southern Medical University, Foshan, 528000, China.
Background:
High-intensity focused ultrasound cyclo-plasty (UCP) is a recently developed glaucoma surgery. This study collected and analysed the clinical data of patients who underwent UCP to observe the efficacy and safety of this surgery in Chinese glaucoma patients.
Methods:
This was a retrospective study. The clinical data of all the patients who underwent UCP at Affiliated Foshan Hospital, Southern Medical University, were collected and analysed to evaluate the efficacy and safety of UCP. The main outcome measure was intraocular pressure, and the secondary outcome measures were best corrected visual acuity (logMAR) and complications.
Results:
Fifty-eight patients (61 eyes) were recruited for this study. IOP was dramatically decreased during the 12 months after UCP (p<0.05). The median IOP reduction during the 18 months post-procedure was more than 30%. The greatest reduction was at 1 month post-UCP (60.86%). The qualified success rate was more than 60% during the 18-month follow-up (Fig. 1). Poor follow up was found after 6-month post-UCP. The highest success rate was obtained at 7 days post-UCP (94.55%). No statistically significant decrease in BCVA in the vison group was observed at the follow-up visits, except for 1 day post-UCP. There was a statistically significant reduction in the use of IOP lowering medications during the 6 months post-UCP. No severe complications occurred.
Conclusion:
UCP is a safe and effective procedure for primary and refractive glaucoma at least during the 6 months post-UCP procedure. Studies with longer follow-up time and better follow up are needed to further confirm the long-term efficacy and safety of UCP in Chinese glaucoma patients.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
10:10Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
Published on: February 15, 2022
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview