Related Experiment Video
Updated: Aug 26, 2025

In Silico Clinical Trials for Cardiovascular Disease
Published on: May 27, 2022
Numerical simulation of transcatheter mitral valve replacement: The dynamic implication of LVOT obstruction in the
Salvatore Pasta1, Chiara Catalano2, Stefano Cannata3
1Department of Engineering, Viale delle Scienze, Università degli Studi di Palermo, Palermo, Italy; Department of Bioengineering Research, IRCCS-ISMETT, Palermo, Italy.
Abstract:
Transcatheter mitral valve replacement (TMVR) has been used for "off-label" treatment when annuloplasty band ring for mitral repair fails. However, the complex anatomy and function of the mitral valve may lead to fatal complications as a result of the left ventricular outflow tract (LVOT) obstruction in TMVR. We report the structural and hemodynamic response of LVOT obstruction resulting from TMVR with the Edwards SAPIEN 3 Ultra (S3) device. We modified the original Living Heart Human Model (LHHM) to account for a failed mitral valve with an annuloplasty band ring and simulated the cardiac beating condition in the setting of S3 device implantation. Findings demonstrated a high dynamic behavior of the newly formed LVOT (neoLVOT) as confined by the displaced mitral valve and the interventricular septum. During the cardiac beat, the neoLVOT area oscillated from a maximum of 472.1 mm2 at early systole to the minimum of 183 mm2 at end-systole. The profile of both anchoring force and contact pressure revealed that the band ring serves as the anchoring zone while mitral valve is primally displaced by the deployed device. At early systole, computational flow dynamics highlighted hemodynamic disturbances associated with the LVOT obstruction, with a skewed flow towards the septum and a pressured drop of 4.5 mmHg between the left ventricular apex and the neoLVOT region. This study can lead to a more accurate assessment of the risk induced by the LVOT obstruction when stratifying patient anatomic suitability for TMVR.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:42An Image Guided Transapical Mitral Valve Leaflet Puncture Model of Controlled Volume Overload from Mitral Regurgitation in the Rat
Published on: May 19, 2020
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mitral Stenosis IV: Nursing Management
Mitral Valve Prolapse II: Assessment and Management