Nasal pillow vs. standard nasal mask for treatment of OSA: a systematic review and meta-analysis
Bo Deng1, Fei Lai1, Manman Zhang1
1Department of Otolaryngology Head and Neck Surgery, Chengdu Longquanyi First People's Hospital, Chengdu, China.
Purpose:
The purpose of this study was to compare the effectiveness of nasal pillows with standard nasal masks in the treatment of patients with obstructive sleep apnea (OSA).
Methods:
A digitalized search was carried out in four different databases including PubMed, Scopus, EMBASE, and CENTRAL using relevant keywords along with a manual search in relevant journals. All comparative studies comparing outcomes of using a nasal pillow with the use of standard nasal masks for continuous positive airway pressure (CPAP) treatment in patients with OSA were included. The qualitative analysis was carried out by tabulating the demographic data. The quantitative data were subjected to meta-analysis. The quality of comparative studies (both retrospective and prospective cohorts) was evaluated using New-castle Ottawa scale (NOS).
Results:
A total of 14 studies (eight prospective and six retrospective) were included in the review. Of them, five studies were randomized and were of cross-over study design. No significant differences were observed in achieved CPAP and residual apnea-hypopnea index (AHI) levels between the nasal pillow and nasal mask with SMD - 0.05 95% CI [- 0.18, 0.09], p = 0.50 and SMD - 0.13 95% CI [- 0.28, 0.03], p = 0.12, respectively. However, nasal pillow usage was associated with better CPAP adherence with a difference of only + 0.29 min/night as compared to a standard nasal mask, with SMD 0.29 95% CI [0.07, 0.50], p = 0.009.
Conclusion:
Nasal pillow and standard nasal mask were equally effective in terms of residual AHI level and achieved similar therapeutic CPAP pressures. However, the difference in CPAP adherence between groups, though statistically significant, is of questionable clinical significance.
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
06:13Endoscopic Septoplasty with Limited Two-line Resection: Minimally Invasive Surgery for Septal Deviation
Published on: June 20, 2018
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Suctioning the Nasopharyngeal Airway
Equipment Required
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Sleep Apnea
The condition is more prevalent among...
Cardiopulmonary Resuscitation II: ACLS Airway Management