Comprehensive chiral GC-MS/MS and LC-MS/MS methods for identification and determination of N-acyl homoserine lactones
Ondřej Horáček1, Abiud E Portillo2, Umang Dhaubhadel2
1Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX, USA; Department of Pharmaceutical Chemistry and Pharmaceutical Analysis, Charles University, Faculty of Pharmacy, Hradec Kralove, Czech Republic.
Abstract:
N-acyl homoserine lactones (N-HLs) are signaling molecules synthesized by gram-negative bacteria to communicate in a process called quorum sensing. Most reported methods for the analysis of N-HLs, which are chiral molecules, do not distinguish between enantiomers. Typical examples include biosensors, liquid chromatography with UV detection, gas chromatography coupled with a mass spectrometer (GC-MS) and liquid chromatography coupled with mass spectrometer (LC-MS). Recently, the production of both D,L-N-HLs have been reported in Vibrio fischeri and Burkholderia cepacia. Concentrations of the D-N-HLs were found at the limit of quantification for the employed method. Therefore, for further studies of the role of the D-N-HLs in bacterial physiology, more sensitive, reliable, and selective analytical methods are necessary. In this work, such comprehensive chiral analytical methods for the identification and determination of 18 N-HLs using solid phase extraction followed by GC-MS/MS and LC-MS/MS analyses were developed. Extraction recoveries for the more hydrophilic C4 N-HLs were <10% of all other N-HLs, thus offering a possible explanation as to their lack of detection in previous studies. The chiral separations of all 18 N-HLs derivatives were accomplished by the complementary GC-MS/MS and LC-MS/MS methods. The limit of detection for LC-MS/MS method was as low as 1 ppb. The limit of detection for the GC-MS/MS method was found to be one to three orders of magnitude higher than the LC-MS/MS method. Due to the high extraction recovery and a preconcentration factor of 100, concentrations as low as 10 ppt can be detected by LC-MS/MS in biological samples. The LC-MS/MS approach provided greater enantioselectivity for the larger, more hydrophobic N-HLs while GC-MS/MS provided better enantioselectivity for the smaller N-HLs.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
08:53Quantitative and Qualitative Method for Sphingomyelin by LC-MS Using Two Stable Isotopically Labeled Sphingomyelin Species
Published on: May 7, 2018
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)