Related Experiment Video
Updated: Aug 26, 2025

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
[Rapid determination of 16 polycyclic aromatic hydrocarbons in atmospheric fine particles by molecularly imprinted
Yingzi Han1, Xinyue Li1, Hua Pang2
1Weinan Center for Disease Control and Prevention, Weinan 714000, China.
Objective:
A high performance liquid chromatographic method based on the purification of polycyclic aromatic hydrocarbon molecularly imprinted columns was developed, this method was used for the rapid quantitative determination of 16 polycyclic aromatic hydrocarbons(PAHs) in fine particulate matter(PM_(2.5)).
Methods:
The polycyclic aromatic hydrocarbons of the sample were extracted with acetonitrile ultrasonically, purified by molecular imprinting column(MIP-PAHs), and tested after being concentrated by nitrogen blowing.
Results:
The 16 PAHs showed a good linear relationship in the range of 1-40 ng/mL, and the correlation coefficient r>0.9996; the recoveries were 77.13%-107.67% at the three standard addition levels of 5.0, 10.0 and 20.0 ng/mL, the relative standard deviation was 0.15%-4.63%(n=7); the detection limit of the method was 0.004-0.078 ng/m~3, and the quantification limit was 0.016-0.336 ng/m~3.
Conclusion:
The detection of 16 PAHs in PM_(2.5) using this method is more accurate, more sensitive and less time consuming than the result of the simple ultrasonic extraction method and the Soxhlet extraction method in Determination of PAHs in ambient air and exhaust gases in gas phase and particulate matter by high performance liquid chromatography(HJ 647-2013).
More Related Videos
08:58High-Throughput Measurement and Classification of Organic P in Environmental Samples
Published on: June 8, 2011
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation