Diaphragm electrical activity during weaning of nasal high-flow therapy in preterm infants
Rebecca Naples1,2, Alan C Fenton3, Malcolm Brodlie2,4
1Newcastle Neonatal Service, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK rebecca.naples@nhs.net.
Objective:
To determine whether electrical activity of the diaphragm (Edi) changes with weaning nasal high-flow (HF) therapy in preterm infants according to a standardised protocol.
Design:
Prospective observational cohort study.
Setting:
Neonatal intensive care unit.
Patients:
Preterm infants born at <32 weeks gestation, receiving nasal HF as part of routine clinical care.
Interventions:
Infants recruited to the study had their HF weaned according to set clinical criteria. Edi was measured using a modified gastric feeding tube serially from baseline (pre-wean) to 24-hours post-wean.
Main Outcome Measures:
Change in Edi from baseline was measured at four time points up to 24 hours after weaning. Minimum Edi during expiration, maximum Edi during inspiration and amplitude of the Edi signal (Edidelta) were measured. Clinical parameters (heart rate, respiratory rate and fraction of inspired oxygen) were also recorded.
Results:
Forty preterm infants were recruited at a mean corrected gestational age of 31.6 (±2.7) weeks. Data from 156 weaning steps were analysed, 91% of which were successful. Edi did not change significantly from baseline during flow reduction steps, but a significant increase in diaphragm activity was observed when discontinuing HF (median increase in Edidelta immediately post-discontinuation 1.7 µV (95% CI: 0.6 to 3.0)) and at 24 hours 1.9 µV (95% CI: 0.7 to 3.8)). No significant difference in diaphragm activity was observed between successful and unsuccessful weaning steps.
Conclusions:
A protocolised approach to weaning has a high probability of success. Edi does not change with reducing HF rate, but significantly increases with discontinuation of HF from 2 L/min.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pulmonary Cycle: Exhalation
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Nasopharyngeal Airway
Equipment Required