Estimation of systolic blood pressure by Random Forest using heart sounds and a ballistocardiogram
Rafael Gonzalez-Landaeta1, Brenda Ramirez1, Jose Mejia2
1Department of Electrical and Computer Engineering, Autonomous University of Ciudad Juarez, 32310, Ciudad Juárez, Mexico.
Abstract:
Cuffless blood pressure measurement enables unobtrusive and continuous monitoring that can be integrated with wearable devices to extend healthcare to non-hospital settings. Most of the current research has focused on the estimation of blood pressure based on pulse transit time or pulse arrival time using ECG or peripheral cardiac pulse signals as proximal time references. This study proposed the use of a phonocardiogram (PCG) and ballistocardiogram (BCG), two signals detected noninvasively, to estimate systolic blood pressure (SBP). For this, the PCG and the BCG were simultaneously measured in 21 volunteers in the rest, activity, and post-activity conditions. Different features were considered based on the relationships between these signals. The intervals between S1 and S2 of the PCG and the I, J, and K waves of the BCG were statistically analyzed. The IJ and JK slopes were also estimated as additional features to train the machine-learning algorithm. The intervals S1-J, S1-K, S1-I, J-S2, and I-S2 were negatively correlated with changes in SBP (p-val < 0.01). The features were used as explanatory variables for a regressor based on the Random Forest. It was possible to estimate the systolic blood pressure with a mean error of 3.3 mmHg with a standard deviation of ± 5 mmHg. Therefore, we foresee that this proposal has potential applications for wearable devices that use low-cost embedded systems.
More Related Videos
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure